Equipment and Process Validation for an Industrial VH2O2 Sterilization Application

Sterilization of sensitive drug delivery devices such as pre-filled syringes can be significantly enable by implementing Vaporized Hydrogen Peroxide VH2O2 (VHP) Low Temperature Sterilization for the process application. Utilizing VH2O2 has been widely used in biodecontamination of e.g., Pharmaceutical manufacturing spaces, isolators and lyophilizers for over 30 years, and terminal sterilization of sensitive combination products and other medical devices by VH2O2 also increasingly for the past 20 years. The 2022 published ISO 22441 for process validation, adoption by FDA and several other countries and FDA moving VH2O2 sterilization to Established Category A are strengthening its position. The near future EN 17180 for VH2O2 sterilizer equipment will provide specific guidance for implementing to pharmaceutical manufacturing process. Further, the work on VH2O2 specific biological indicator standard ISO 11138-6 and upcoming revision of the AAMI TIR 17 for guidance on material compatibility for sterilization modalities, will provide additional help and guidance. This presentation will provide guidance on all key elements of equipment and process validation of VH2O2 sterilizers and developed processes and recommendation on steps of application implementation, and also puts focus on key requirements of conformance and related materials and documentation, in the light of typical product applications sterilized by VH2O2.

Authors

Institutions

Publication Details

Journal
PDA Journal of Pharmaceutical Science and Technology
Published
2025-01-01
DOI
https://doi.org/10.5731/pdajpst.2025.25426
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Equipment and Process Validation for an Industrial VH2O2 Sterilization Application

Mary Van Gaasbeck Carico
PDA Journal of Pharmaceutical Science and Technology
Medical Device Sterilization and Disinfection
article

Equipment and Process Validation for an Industrial VH2O2 Sterilization Application

Mary Van Gaasbeck Carico
article en

Abstract

Sterilization of sensitive drug delivery devices such as pre-filled syringes can be significantly enable by implementing Vaporized Hydrogen Peroxide VH2O2 (VHP) Low Temperature Sterilization for the process application. Utilizing VH2O2 has been widely used in biodecontamination of e.g., Pharmaceutical manufacturing spaces, isolators and lyophilizers for over 30 years, and terminal sterilization of sensitive combination products and other medical devices by VH2O2 also increasingly for the past 20 years. The 2022 published ISO 22441 for process validation, adoption by FDA and several other countries and FDA moving VH2O2 sterilization to Established Category A are strengthening its position. The near future EN 17180 for VH2O2 sterilizer equipment will provide specific guidance for implementing to pharmaceutical manufacturing process. Further, the work on VH2O2 specific biological indicator standard ISO 11138-6 and upcoming revision of the AAMI TIR 17 for guidance on material compatibility for sterilization modalities, will provide additional help and guidance. This presentation will provide guidance on all key elements of equipment and process validation of VH2O2 sterilizers and developed processes and recommendation on steps of application implementation, and also puts focus on key requirements of conformance and related materials and documentation, in the light of typical product applications sterilized by VH2O2.

PDA Journal of Pharmaceutical Science and TechnologyVol. 79(4)
Steris (United States) (US)
Openalex Percentile: Top 82%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.