Method development and validation of mestranol tablets by RP-HPLC

The present project work was to use the RP-HPLC technique to estimate mestranol concurrently in tablet dose forms and to verify the procedure in compliance with ICH standards. Chromatogram was performed using Inertsil ODS C18 column 250 x 4.6 mm with 5um. Mobile phase acetonitrile: methanol in ratio of 25:75 used was pumped at a flow rate of 1ml/min. injection volume 20 ul with a run time of 6 min. The retention time, optimized wavelength was found at 238nm at ambient temperature. Limit of detection and limit of quantification was found to be 0.012 & 0.036 and with a regression equation of y = 5570.5x + 105.33 R² = 0.999. Hence the developed method is simple and found to be economical to be adopted for mestranol estimation.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutical Research and Development
Published
2025-01-01
DOI
https://doi.org/10.33545/26646862.2025.v7.i2b.170
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method development and validation of mestranol tablets by RP-HPLC

Shashikant Desai, Chittampally Pranathi, K. Sunitha, G Manushri et al.
International Journal of Pharmaceutical Research and Development
Analytical Methods in Pharmaceuticals
article

Method development and validation of mestranol tablets by RP-HPLC

Shashikant Desai, Chittampally Pranathi, K. Sunitha, G Manushri, N Thriveni, Neyaz
article en

Abstract

The present project work was to use the RP-HPLC technique to estimate mestranol concurrently in tablet dose forms and to verify the procedure in compliance with ICH standards. Chromatogram was performed using Inertsil ODS C18 column 250 x 4.6 mm with 5um. Mobile phase acetonitrile: methanol in ratio of 25:75 used was pumped at a flow rate of 1ml/min. injection volume 20 ul with a run time of 6 min. The retention time, optimized wavelength was found at 238nm at ambient temperature. Limit of detection and limit of quantification was found to be 0.012 & 0.036 and with a regression equation of y = 5570.5x + 105.33 R² = 0.999. Hence the developed method is simple and found to be economical to be adopted for mestranol estimation.

International Journal of Pharmaceutical Research and DevelopmentVol. 7(2)
National Institute of Pharmaceutical Education and Research - Ahmedabad (IN), Sree Balaji Dental College and Hospital (IN)
Openalex Percentile: Top 79%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Method development and validation of mestranol tablets by RP-HPLC — Shashikant Desai, Chittampally Pranathi, et al. · International Journal of Pharmaceutical Research and Development (2025) | TGRS Research Map | TGRS