Methodological approach for a simultaneous determination of persistent and non-persistent organic pollutants in human blood (serum/plasma) using gas chromatography and mass spectrometry techniques

Human biomonitoring of persistent organic pollutants (POPs) remains essential for tracking long-term exposure, evaluating health risks, and assessing the effectiveness of regulatory bans. For this purpose, an experimental and analytical methodology has been optimized allowing the determination of 47 POPs, encompassing chlorinated cyclodienes, chlorobenzenes, cyclohexanes, polychlorodiphenyl derivatives, several congeners of polychlorobiphenyls (PCBs) and polybromodiphenyl ethers (PBDEs, including the deca-BDE), as well as three non-persistent chemicals (namely quintozene, tecnazene and vinclozolin). The method uses a single liquid-liquid extraction procedure with 500 µL of serum/plasma. Instrumental analysis involves gas chromatography (GC) with electron capture detection (ECD) for the analysis of organochlorines, and a subsequent injection into a GC coupled to mass spectrometry in negative chemical ionization mode (MS-NCI) for the determination of PBDEs. The analytical procedure has been successfully validated, demonstrating high sensitivity (limits of detection: 0.0016-0.012 ng/mL; limits of quantification: 0.0029-0.021 ng/mL), acceptable linearity (R² > 0.9962), good precision (coefficients of variation <25%, except for BDE-209), satisfactory accuracy (recoveries within 70-130% for 41 out of 47 compounds) and minimal matrix effects. Proficiency Testing Materials from the AMAP Ring Test for POPs in human serum confirmed the method's reliability with results within the accepted reference range. This method represents an efficient and practical approach for human biomonitoring studies, with a simplified workflow suitable for routine application.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2025-07-19
DOI
https://doi.org/10.1016/j.chroma.2025.466235
Citations
1
Primary Topic
Toxic Organic Pollutants Impact
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methodological approach for a simultaneous determination of persistent and non-persistent organic pollutants in human blood (serum/plasma) using gas chromatography and mass spectrometry techniques

Natalia Bravo, Mercè Garí, Carolina M Bustamante, Joan O Grimalt et al.
1 citations
Journal of Chromatography A
Toxic Organic Pollutants Impact
1.20
article

Methodological approach for a simultaneous determination of persistent and non-persistent organic pollutants in human blood (serum/plasma) using gas chromatography and mass spectrometry techniques

Natalia Bravo, Mercè Garí, Carolina M Bustamante, Joan O Grimalt, Paula Ruiz, Atiya B Rifat
article en
1 citations

Abstract

Human biomonitoring of persistent organic pollutants (POPs) remains essential for tracking long-term exposure, evaluating health risks, and assessing the effectiveness of regulatory bans. For this purpose, an experimental and analytical methodology has been optimized allowing the determination of 47 POPs, encompassing chlorinated cyclodienes, chlorobenzenes, cyclohexanes, polychlorodiphenyl derivatives, several congeners of polychlorobiphenyls (PCBs) and polybromodiphenyl ethers (PBDEs, including the deca-BDE), as well as three non-persistent chemicals (namely quintozene, tecnazene and vinclozolin). The method uses a single liquid-liquid extraction procedure with 500 µL of serum/plasma. Instrumental analysis involves gas chromatography (GC) with electron capture detection (ECD) for the analysis of organochlorines, and a subsequent injection into a GC coupled to mass spectrometry in negative chemical ionization mode (MS-NCI) for the determination of PBDEs. The analytical procedure has been successfully validated, demonstrating high sensitivity (limits of detection: 0.0016-0.012 ng/mL; limits of quantification: 0.0029-0.021 ng/mL), acceptable linearity (R² > 0.9962), good precision (coefficients of variation <25%, except for BDE-209), satisfactory accuracy (recoveries within 70-130% for 41 out of 47 compounds) and minimal matrix effects. Proficiency Testing Materials from the AMAP Ring Test for POPs in human serum confirmed the method's reliability with results within the accepted reference range. This method represents an efficient and practical approach for human biomonitoring studies, with a simplified workflow suitable for routine application.

Journal of Chromatography AVol. 1759
University of the Basque Country (ES), Institute of Environmental Assessment and Water Research (ES)
Openalex Percentile: Top 20%
Toxic Organic Pollutants Impact
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.