Visual Outcomes of a New Hydrophobic Trifocal Intraocular Lens in Cataract Treatment: A Prospective Clinical Study
<b>Purpose:</b> To report the visual outcomes following bilateral implantation of a new trifocal intraocular lens (IOL) in patients with age-related cataracts. <b>Methods:</b> This prospective, noncomparative, multicenter study assessed 126 patients undergoing cataract extraction followed by AT ELANA 841P IOL implantation. At 4-6 months postoperatively, refractive error and predictability, monocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance-corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA), distance-corrected near visual acuity (DCNVA), and binocular contrast sensitivity were measured. The binocular defocus curve was evaluated at 3 months postoperatively. <b>Results:</b> Postoperatively, most of the eyes (84.9%) were within ±0.5 D of spherical equivalent (SE) refraction and almost all eyes (98.9%) within ±1.0 D, with a mean SE value of -0.11 ± 0.37 D. Mean monocular CDVA was -0.06 ± 0.08 logMAR and UDVA was -0.01 ± 0.10 logMAR. Mean monocular uncorrected (UIVA and UNVA) and distance-corrected visual acuities (DCIVA and DCNVA) were 0.1 logMAR or better at intermediate (80 cm) and near (40 cm) distances. In the mean defocus curve, a continuous range of 0.1 logMAR or better vision from distance to near was observed. Percentages of eyes achieving CDVA, DCIVA, and DCNVA of 0.1 logMAR or better were 97.2%, 59.1% and 59.1%, respectively. Uncorrected visual acuity of 0.1 logMAR or better was achieved in 88.9% of the eyes at far, 57.1% at intermediate, and 44.4% at near distances. Contrast sensitivity was in the normal range of a phakic population at all spatial frequencies in all light conditions tested, photopic with glare and mesopic with and without glare. <b>Conclusion:</b> Implantation of the new AT ELANA 841P IOL following cataract extraction is safe and effective. Visual acuities at all distances, refractive outcomes, and contrast sensitivity were favorable at 4-6 months postoperatively, providing patients with satisfactory far, intermediate, and near vision. <b>Trial registration:</b> ClinicalTrials.gov identifier: NCT06247683.
Authors
- Pavol Veselý (ORCID: https://orcid.org/0000-0002-2972-223X)
- Marek Káčerik (ORCID: https://orcid.org/0009-0003-3086-0677)
- Iveta Němcová (ORCID: https://orcid.org/0000-0001-5410-7338)
- Lucia Hrčková
- Peter Mojžíš (ORCID: https://orcid.org/0000-0001-5109-1959)
- Andrea Janeková (ORCID: https://orcid.org/0000-0003-2644-4139)
Institutions
- Charles University (CZ)
- Vysoká škola manažmentu, City University of Seattle (SK)
- Havlíčkův Brod Hospital (CZ)
- Eye Center (SA)
- Military University Hospital Prague (CZ)
- University of Hradec Králové (CZ)
Publication Details
- Journal
- Journal of Ophthalmology
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1155/joph/2662730
- Citations
- 1
- Primary Topic
- Ocular Surface and Contact Lens
- Type
- article
- Field-Weighted Citation Impact
- 1.88
Funders
- Carl Zeiss Meditec AG