Enhancing Seizure Detection Accuracy in Wearable EEG Devices Using Deep Learning Algorithms

Wearable electroencephalography (EEG) devices for seizure detection accuracy and reliability are deep learning (DL) applications in the field of epilepsy diagnosis. In this study, we sought to increase the accuracy of seizure detection using advanced DL algorithms on the Children’s Hospital Boston - Massachusetts Institute of Technology (CHB-MIT) EEG database. First, a fully convolutional network (FCN) was trained and assessed using accuracy and recall/precision metrics, and the early stopping technique was used to avoid overfitting. To assess the performance, the FCN was evaluated in terms of various metrics, including accuracy, precision, recall, F1-score, and receiver operating characteristic (ROC)-area under the curve (AUC). In addition, two-dimensional (2D) convolutional neural networks (CNNs) and long short-term memory (LSTM) models were used to model the database, and their performance was thoroughly measured using different metrics, graphs, and confusion matrices. Using LSTM variants, such as standard LSTM, bidirectional LSTM, stacked LSTM, and LSTM attention mechanisms, hybrid convolutional LSTM (ConvLSTM) models were trained and compared. The comparison was conducted based on the training and validation accuracy and loss, as well as the graphs resulting from the precision–recall curves. Apart from DL approaches, EEG signal analysis using time–frequency techniques, such as wavelet transform and short-time Fourier transform, has also been investigated. These methods assisted in the analysis of the time–frequency features of EEG signals in combination with DL models. This study demonstrates that the performance of wearable EEG devices can be augmented using a combination of DL and seizure signal processing techniques. The FCN achieved an accuracy of 92%, with a recall for seizures of 33%, an F1-score of 0.03, and strong ROC-AUC results. The 2D CNN achieved 96% accuracy, a seizure recall of 70%, an F1-score of 0.12, and an ROC-AUC score of 78%. The baseline LSTM struggled with effectiveness at 53% accuracy with a seizure recall of 18%. In contrast, the LSTM model, which incorporated synthetic minority oversampling technique (SMOTE) balancing, was able to reach improvements of up to 89% accuracy, with a precision of 91%, a recall of 86%, an F1-score of 0.89, and a strong ROC curve performance. Among the models, the LSTM with SMOTE was the best performer, with 89% accuracy, 91% precision, 86% recall, and an F1-score of 0.89. These results provide evidence that applying techniques for data balancing in combination with certain DL network architectures significantly improves the detection of seizures using wearable EEG devices worn on the body. We believe that real-time monitoring and high-performance systems are feasible using optimized DL frameworks. The analysis of the performance of different models allows for the understanding of the possibilities of optimizing the architectures of DL algorithms for the modern diagnosis of epilepsy in real time. The source code used to carry out the experiments is publicly available at CHB-MIT EEG Dataset Python Scripts ( https://www.kaggle.com/code/adnankust/adnaneeg1 ).

Authors

Publication Details

Journal
Journal of Disability Research
Published
2025-01-01
DOI
https://doi.org/10.57197/jdr-2025-0590
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Seizure Detection Accuracy in Wearable EEG Devices Using Deep Learning Algorithms

Mosleh Hmoud Al-Adhaileh, M. Irfan Uddin, Theyazn H. H. Aldhyani, Mohammed Alarfaj et al.
Journal of Disability Research
EEG and Brain-Computer Interfaces
article

Enhancing Seizure Detection Accuracy in Wearable EEG Devices Using Deep Learning Algorithms

Mosleh Hmoud Al-Adhaileh, M. Irfan Uddin, Theyazn H. H. Aldhyani, Mohammed Alarfaj, Muhammad Adnan
article en

Abstract

Wearable electroencephalography (EEG) devices for seizure detection accuracy and reliability are deep learning (DL) applications in the field of epilepsy diagnosis. In this study, we sought to increase the accuracy of seizure detection using advanced DL algorithms on the Children’s Hospital Boston - Massachusetts Institute of Technology (CHB-MIT) EEG database. First, a fully convolutional network (FCN) was trained and assessed using accuracy and recall/precision metrics, and the early stopping technique was used to avoid overfitting. To assess the performance, the FCN was evaluated in terms of various metrics, including accuracy, precision, recall, F1-score, and receiver operating characteristic (ROC)-area under the curve (AUC). In addition, two-dimensional (2D) convolutional neural networks (CNNs) and long short-term memory (LSTM) models were used to model the database, and their performance was thoroughly measured using different metrics, graphs, and confusion matrices. Using LSTM variants, such as standard LSTM, bidirectional LSTM, stacked LSTM, and LSTM attention mechanisms, hybrid convolutional LSTM (ConvLSTM) models were trained and compared. The comparison was conducted based on the training and validation accuracy and loss, as well as the graphs resulting from the precision–recall curves. Apart from DL approaches, EEG signal analysis using time–frequency techniques, such as wavelet transform and short-time Fourier transform, has also been investigated. These methods assisted in the analysis of the time–frequency features of EEG signals in combination with DL models. This study demonstrates that the performance of wearable EEG devices can be augmented using a combination of DL and seizure signal processing techniques. The FCN achieved an accuracy of 92%, with a recall for seizures of 33%, an F1-score of 0.03, and strong ROC-AUC results. The 2D CNN achieved 96% accuracy, a seizure recall of 70%, an F1-score of 0.12, and an ROC-AUC score of 78%. The baseline LSTM struggled with effectiveness at 53% accuracy with a seizure recall of 18%. In contrast, the LSTM model, which incorporated synthetic minority oversampling technique (SMOTE) balancing, was able to reach improvements of up to 89% accuracy, with a precision of 91%, a recall of 86%, an F1-score of 0.89, and a strong ROC curve performance. Among the models, the LSTM with SMOTE was the best performer, with 89% accuracy, 91% precision, 86% recall, and an F1-score of 0.89. These results provide evidence that applying techniques for data balancing in combination with certain DL network architectures significantly improves the detection of seizures using wearable EEG devices worn on the body. We believe that real-time monitoring and high-performance systems are feasible using optimized DL frameworks. The analysis of the performance of different models allows for the understanding of the possibilities of optimizing the architectures of DL algorithms for the modern diagnosis of epilepsy in real time. The source code used to carry out the experiments is publicly available at CHB-MIT EEG Dataset Python Scripts ( https://www.kaggle.com/code/adnankust/adnaneeg1 ).

Journal of Disability ResearchVol. 4(4)
Openalex Percentile: Top 81%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.