Vertebral Body Fracture During Manual Therapy in a Patient Following Spinal Surgery and Previous Instrumentation Removal

Spinal fusion with metallic implants is a widely used surgical approach to manage various spinal pathologies including instability and degenerative diseases. Although spinal instrumentations facilitate successful bone fusion by providing immediate rigid support and stability, their removal may be necessary because of pain, mechanical failure, or infection. However, implant removal, particularly in patients with low bone density, may lead to fractures of the fused vertebral bodies owing to stress-shielding effects. This case report describes a 70-year-old woman with a history of spinal fusion surgery at the L3-L4-L5 levels who underwent another spinal fusion surgery at the L5-S1 level and removal of previous implants owing to adjacent segment disease. During recovery, the patient developed sudden severe back pain due to vertebral body fractures at the L3 and L4 levels following manual therapy. Percutaneous vertebroplasty was performed to treat these fractures and allowed for recovery without any complication. This case highlights the importance of careful preoperative planning and postoperative management in preventing fractures associated with hardware removal.

Authors

Institutions

Publication Details

Journal
Korean Journal of Neurotrauma
Published
2025-01-01
DOI
https://doi.org/10.13004/kjnt.2025.21.e23
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vertebral Body Fracture During Manual Therapy in a Patient Following Spinal Surgery and Previous Instrumentation Removal

Sung-Bum Kim, Jun-Yong Cha, Sang-Soo Choi, Il-Tae Jang
Korean Journal of Neurotrauma
Spine and Intervertebral Disc Pathology
article

Vertebral Body Fracture During Manual Therapy in a Patient Following Spinal Surgery and Previous Instrumentation Removal

Sung-Bum Kim, Jun-Yong Cha, Sang-Soo Choi, Il-Tae Jang
article en

Abstract

Spinal fusion with metallic implants is a widely used surgical approach to manage various spinal pathologies including instability and degenerative diseases. Although spinal instrumentations facilitate successful bone fusion by providing immediate rigid support and stability, their removal may be necessary because of pain, mechanical failure, or infection. However, implant removal, particularly in patients with low bone density, may lead to fractures of the fused vertebral bodies owing to stress-shielding effects. This case report describes a 70-year-old woman with a history of spinal fusion surgery at the L3-L4-L5 levels who underwent another spinal fusion surgery at the L5-S1 level and removal of previous implants owing to adjacent segment disease. During recovery, the patient developed sudden severe back pain due to vertebral body fractures at the L3 and L4 levels following manual therapy. Percutaneous vertebroplasty was performed to treat these fractures and allowed for recovery without any complication. This case highlights the importance of careful preoperative planning and postoperative management in preventing fractures associated with hardware removal.

Korean Journal of NeurotraumaVol. 21(3)
Wooridul Hospital (KR)
Good health and well-being
Openalex Percentile: Top 72%
Spine and Intervertebral Disc Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.