Improvement of a plastic scintillator with different coatings for gamma-ray detection

Identical cubic plastic scintillator detectors were tested using different coating materials in order to investigate their response function and efficiency, additionally two light guides were also coated evaluating their performance in order to find the best combination for a detection array. The array is composed by a plastic scintillator coupled to a light guide and a photomultiplier tube (PMT), the output signal is processed by a Data Aquisition System (DAQ). Operational voltage for the PMT was found and detectors were tested measuring 137Cs certified gamma-ray point source. Spectra were analyzed and optimal coating for light guide and detector combination was determined based on the array’s efficiency.

Authors

Institutions

Publication Details

Journal
EPJ Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/epjconf/202533303005
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of a plastic scintillator with different coatings for gamma-ray detection

D. J. Marı́n-Lámbarri, Luis Alvarez, T. Murrieta-Rodríguez, Claudio I. Valencia et al.
EPJ Web of Conferences
Radiation Detection and Scintillator Technologies
article

Improvement of a plastic scintillator with different coatings for gamma-ray detection

D. J. Marı́n-Lámbarri, Luis Alvarez, T. Murrieta-Rodríguez, Claudio I. Valencia, Óscar Eduardo López-López, Héctor Alva‐Sánchez, A. F. García‐Flores, A. Huerta, J. Méndez-García, A. Farah-Simon
article en

Abstract

Identical cubic plastic scintillator detectors were tested using different coating materials in order to investigate their response function and efficiency, additionally two light guides were also coated evaluating their performance in order to find the best combination for a detection array. The array is composed by a plastic scintillator coupled to a light guide and a photomultiplier tube (PMT), the output signal is processed by a Data Aquisition System (DAQ). Operational voltage for the PMT was found and detectors were tested measuring 137Cs certified gamma-ray point source. Spectra were analyzed and optimal coating for light guide and detector combination was determined based on the array’s efficiency.

EPJ Web of ConferencesVol. 333
Universidad Nacional Autónoma de México (MX)
Openalex Percentile: Top 75%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.