Experimental Demonstration of 32‐PAM Optical Camera Communication Using a Low Cost and a High Cost Camera

ABSTRACT This work demonstrates experimentally the feasibility of using up to 32‐PAM in rolling shutter based optical camera communication (OCC). Two different cameras have been used for OCC performance comparison, namely, a low‐cost Pi Camera V2.1 and a higher‐cost Alvium 1800 U‐500m. Based on the limitations evidenced by this analysis, a decoding algorithm has been proposed to recover the transmitted signal from the acquired images. The experimental evaluation has been carried out for distances up to 2 m, using 8‐PAM, 16‐PAM and 32‐PAM, analysing the received samples histograms and the symbol error rate (SER) for both cameras. Based on the collected experimental results, it is concluded that 32‐PAM is possible with both cameras, with a maximum SER of 0.16% for the Alvium camera and 5.05% for the Pi Camera. Finally, it is observed that both the signal and noise amplitudes remain constant for the tested distances, resulting in a SER that does not notably depend on the distance between the transmitter and receiver.

Authors

Institutions

Publication Details

Journal
IET Optoelectronics
Published
2025-01-01
DOI
https://doi.org/10.1049/ote2.70016
Primary Topic
Optical Wireless Communication Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Demonstration of 32‐PAM Optical Camera Communication Using a Low Cost and a High Cost Camera

Miguel Rêgo, Alexis A. Dowhuszko, Pedro Fonseca, Luís Nero Alves
IET Optoelectronics
Optical Wireless Communication Technologies
article

Experimental Demonstration of 32‐PAM Optical Camera Communication Using a Low Cost and a High Cost Camera

Miguel Rêgo, Alexis A. Dowhuszko, Pedro Fonseca, Luís Nero Alves
article en

Abstract

ABSTRACT This work demonstrates experimentally the feasibility of using up to 32‐PAM in rolling shutter based optical camera communication (OCC). Two different cameras have been used for OCC performance comparison, namely, a low‐cost Pi Camera V2.1 and a higher‐cost Alvium 1800 U‐500m. Based on the limitations evidenced by this analysis, a decoding algorithm has been proposed to recover the transmitted signal from the acquired images. The experimental evaluation has been carried out for distances up to 2 m, using 8‐PAM, 16‐PAM and 32‐PAM, analysing the received samples histograms and the symbol error rate (SER) for both cameras. Based on the collected experimental results, it is concluded that 32‐PAM is possible with both cameras, with a maximum SER of 0.16% for the Alvium camera and 5.05% for the Pi Camera. Finally, it is observed that both the signal and noise amplitudes remain constant for the tested distances, resulting in a SER that does not notably depend on the distance between the transmitter and receiver.

IET OptoelectronicsVol. 19(1)
Instituto de Telecomunicações (PT), University of Aveiro (PT), Aalto University (FI)
European Cooperation in Science and Technology, Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 83%
Optical Wireless Communication Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Demonstration of 32‐PAM Optical Camera Communication Using a Low Cost and a High Cost Camera — Miguel Rêgo, Alexis A. Dowhuszko, et al. · IET Optoelectronics (2025) | TGRS Research Map | TGRS