Clinical and microbiological spectrum of catheter-related bloodstream infections in non-tunneled and tunneled internal jugular vein hemodialysis catheters at a tertiary care hospital in Uttarakhand

Background: Catheter-related bloodstream infection (CRBSI) is a significant cause of morbidity and mortality in patients undergoing hemodialysis. In this prospective cohort study, we studied the incidence rate of CRBSI as well as the clinical and microbiological profile in non-tunneled and tunneled hemodialysis catheters. Methods: Patients were recruited as per inclusion/exclusion criteria. Patients with non-tunneled internal jugular catheters were followed for 1 month and tunneled internal jugular were followed for 3 months. Patients with clinical signs and symptoms suggestive of CRBSI were admitted. We followed the centers for disease control and prevention (CDC) guidelines for the diagnosis of catheter-associated bloodstream infections microbiological methods-blood samples were inoculated on an automated BACTEC system for 5 days. If microbial growth was detected by the automated system, Gram staining was performed and growth was sub-cultured on culture media. Results: The 202 patients underwent internal jugular vein hemodialysis catheter insertion. The 21 patients were excluded from the study. Total 181 patients were confirmed eligible. The 16.0% of the participants (29 patients) developed CRBSI during follow up. Incidence of CRBSI in our study was 3.73 episodes per 1000 catheter days. Diabetes mellitus and low BMI were risk factors for CRBSI. Most of the CRBSI were caused by gram negative organism. Overall, 65.5% of CRBSI were caused by multidrug resistant organisms. Conclusions: Incidence of CRBSI was high in non-tunneled catheters as compared to tunneled catheters.

Authors

Institutions

Publication Details

Journal
International Journal of Research in Medical Sciences
Published
2025-07-30
DOI
https://doi.org/10.18203/2320-6012.ijrms20252390
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical and microbiological spectrum of catheter-related bloodstream infections in non-tunneled and tunneled internal jugular vein hemodialysis catheters at a tertiary care hospital in Uttarakhand

Arshdeep Singh, Sharon Kandari, Sandeep Kaur, Mahendra Singh et al.
2 links
International Journal of Research in Medical Sciences
Central Venous Catheters and Hemodialysis
article

Clinical and microbiological spectrum of catheter-related bloodstream infections in non-tunneled and tunneled internal jugular vein hemodialysis catheters at a tertiary care hospital in Uttarakhand

Arshdeep Singh, Sharon Kandari, Sandeep Kaur, Mahendra Singh, Sandeep Saini, Anshuman Biswal, Rohit Puri, Parul Ahlawat, Anil Cheriyan, Abhay Gangdev
article en

Abstract

Background: Catheter-related bloodstream infection (CRBSI) is a significant cause of morbidity and mortality in patients undergoing hemodialysis. In this prospective cohort study, we studied the incidence rate of CRBSI as well as the clinical and microbiological profile in non-tunneled and tunneled hemodialysis catheters. Methods: Patients were recruited as per inclusion/exclusion criteria. Patients with non-tunneled internal jugular catheters were followed for 1 month and tunneled internal jugular were followed for 3 months. Patients with clinical signs and symptoms suggestive of CRBSI were admitted. We followed the centers for disease control and prevention (CDC) guidelines for the diagnosis of catheter-associated bloodstream infections microbiological methods-blood samples were inoculated on an automated BACTEC system for 5 days. If microbial growth was detected by the automated system, Gram staining was performed and growth was sub-cultured on culture media. Results: The 202 patients underwent internal jugular vein hemodialysis catheter insertion. The 21 patients were excluded from the study. Total 181 patients were confirmed eligible. The 16.0% of the participants (29 patients) developed CRBSI during follow up. Incidence of CRBSI in our study was 3.73 episodes per 1000 catheter days. Diabetes mellitus and low BMI were risk factors for CRBSI. Most of the CRBSI were caused by gram negative organism. Overall, 65.5% of CRBSI were caused by multidrug resistant organisms. Conclusions: Incidence of CRBSI was high in non-tunneled catheters as compared to tunneled catheters.

International Journal of Research in Medical SciencesVol. 13(8)
All India Institute of Medical Sciences Rishikesh (IN)
Openalex Percentile: Top 70%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.