On the analysis of functional PET (fPET)-FDG: Baseline mischaracterization can introduce artifactual metabolic (de)activations

Functional Positron Emission Tomography (fPET) with (bolus plus) constant infusion of [<sup>18</sup>F]-fluorodeoxyglucose (FDG), known as fPET-FDG, is a recently introduced technique in human neuroimaging, enabling the detection of dynamic glucose metabolism changes within a single scan. However, the statistical analysis of fPET-FDG data remains challenging because its signal and noise characteristics differ from both classic bolus-administration FDG PET and from functional Magnetic Resonance Imaging (fMRI), which together compose the primary sources of inspiration for analytical methods used by fPET-FDG researchers. In this study, we present an investigation of how inaccuracies in modeling baseline FDG uptake can introduce artifactual patterns to detrended time-activity curve (TAC) residuals, potentially introducing spurious (de)activations to general linear model (GLM) analyses. By combining simulations and empirical data from both constant infusion and bolus-plus-constant infusion protocols, we evaluate the effects of various baseline modeling methods, including polynomial detrending, regression against the global mean time-activity curve, and two analytical methods based on tissue compartment model kinetics. Our findings indicate that improper baseline removal can introduce statistically significant artifactual effects, although these effects characterized in this study (~2-8%) are generally smaller than those reported by previous literature employing robust sensory stimulation (~10-30%). We discuss potential strategies to mitigate this issue, including informed baseline modeling, optimized tracer administration protocols, and careful experimental design. These insights aim to enhance the reliability of fPET-FDG in capturing true metabolic dynamics in neuroimaging research.

Authors

Institutions

Publication Details

Journal
Imaging Neuroscience
Published
2025-01-01
DOI
https://doi.org/10.1162/imag.a.110
Citations
4
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
5.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the analysis of functional PET (fPET)-FDG: Baseline mischaracterization can introduce artifactual metabolic (de)activations

Arun Garimella, Jingyuan E. Chen, Hasan Sari, Rupert R. Lanzenberger et al.
4 citations
Imaging Neuroscience
Medical Imaging Techniques and Applications
5.44
article

On the analysis of functional PET (fPET)-FDG: Baseline mischaracterization can introduce artifactual metabolic (de)activations

Arun Garimella, Jingyuan E. Chen, Hasan Sari, Rupert R. Lanzenberger, Grant Hartung, Andreas Hahn, Jon̈athan R. Polimeni, Douglas N. Greve, Julie C. Price, Joseph B. Mandeville, Murray Bruce Reed, Sean E. Coursey
article en
4 citations

Abstract

Functional Positron Emission Tomography (fPET) with (bolus plus) constant infusion of [<sup>18</sup>F]-fluorodeoxyglucose (FDG), known as fPET-FDG, is a recently introduced technique in human neuroimaging, enabling the detection of dynamic glucose metabolism changes within a single scan. However, the statistical analysis of fPET-FDG data remains challenging because its signal and noise characteristics differ from both classic bolus-administration FDG PET and from functional Magnetic Resonance Imaging (fMRI), which together compose the primary sources of inspiration for analytical methods used by fPET-FDG researchers. In this study, we present an investigation of how inaccuracies in modeling baseline FDG uptake can introduce artifactual patterns to detrended time-activity curve (TAC) residuals, potentially introducing spurious (de)activations to general linear model (GLM) analyses. By combining simulations and empirical data from both constant infusion and bolus-plus-constant infusion protocols, we evaluate the effects of various baseline modeling methods, including polynomial detrending, regression against the global mean time-activity curve, and two analytical methods based on tissue compartment model kinetics. Our findings indicate that improper baseline removal can introduce statistically significant artifactual effects, although these effects characterized in this study (~2-8%) are generally smaller than those reported by previous literature employing robust sensory stimulation (~10-30%). We discuss potential strategies to mitigate this issue, including informed baseline modeling, optimized tracer administration protocols, and careful experimental design. These insights aim to enhance the reliability of fPET-FDG in capturing true metabolic dynamics in neuroimaging research.

Imaging NeuroscienceVol. 3
Northeastern University (US), Harvard University (US), Massachusetts General Hospital (US), Harvard–MIT Division of Health Sciences and Technology (US), Athinoula A. Martinos Center for Biomedical Imaging (US), Siemens (Switzerland) (CH), Massachusetts Institute of Technology (US), Medical University of Vienna (AT)
Brain and Behavior Research Foundation, BrightFocus Foundation, Massachusetts Life Sciences Center, Centre d'Imagerie BioMédicale, National Institutes of Health, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 4%
Medical Imaging Techniques and Applications
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.