Computational investigation and exergy analysis of swirling flow in vortex tube

A vortex tube is very useful in several process industries to solve the spot cooling problem.Owing to its very small size and high pressure of working fluid, experimental analysis and determination of flow parameters of vortex tube becomes very difficult task.The present work attempts to explore and utilise the philosophy of computational fluid dynamics in an effort to overcome the limitations of experimental investigations.Simulation has been performed for turbulent, swirling, compressible flow of air at various inlet pressures using Standard k- turbulence model.The results of the computational model are validated against experimental results as well as computational results of previously published works through comparison of temperature separation magnitude on % basis as well as non-dimensional basis.The variation between experimental and computational results is about 8%.Thereafter, grid independence of solution is checked to circumvent the errors pertaining to grid's coarseness.Previously, many of the research works on exergy analysis of vortex tube have been conducted for constant values of cold mass ratio, whilst in the present work, performance has been checked for different cold mass ratios as well as inlet pressure values.The inlet pressure values are selected pertaining to common scenario in process industries.It is inferred from the results that the computational model is able to replicate the exergetic behaviour of vortex tube with good agreement.As hypothesized at the beginning of this research, cold mass ratio is found to be indeed an important parameter from both energy as well as exergy analysis point of view.The amount of inlet total exergy is 559 W at 200 kPa, 966 W at 300 kPa, 1352.71W at 400 kPa, 1538.86W at 486 kPa, 1732.29 W at 500 kPa and 2174.54W at 600 kPa inlet pressure.Maximum cold exergy efficiency of 27.77% and hot exergy efficiency of 39.39% is observed at inlet pressure of 600 kPa.Total exergy efficiency shows minimum value for cold mass ratios in the range of 0.4 to 0.6.Cold-end exergy efficiency is observed to be more affected due to inlet pressure than hot-end exergy efficiency.

Authors

Publication Details

Journal
Journal of Thermal Engineering
Published
2025-01-01
DOI
https://doi.org/10.14744/thermal.0000959
Citations
1
Primary Topic
Ranque-Hilsch vortex tube
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational investigation and exergy analysis of swirling flow in vortex tube

Hitesh R. Thakare
1 citations
Journal of Thermal Engineering
Ranque-Hilsch vortex tube
0.71
article

Computational investigation and exergy analysis of swirling flow in vortex tube

Hitesh R. Thakare
article en
1 citations

Abstract

A vortex tube is very useful in several process industries to solve the spot cooling problem.Owing to its very small size and high pressure of working fluid, experimental analysis and determination of flow parameters of vortex tube becomes very difficult task.The present work attempts to explore and utilise the philosophy of computational fluid dynamics in an effort to overcome the limitations of experimental investigations.Simulation has been performed for turbulent, swirling, compressible flow of air at various inlet pressures using Standard k- turbulence model.The results of the computational model are validated against experimental results as well as computational results of previously published works through comparison of temperature separation magnitude on % basis as well as non-dimensional basis.The variation between experimental and computational results is about 8%.Thereafter, grid independence of solution is checked to circumvent the errors pertaining to grid's coarseness.Previously, many of the research works on exergy analysis of vortex tube have been conducted for constant values of cold mass ratio, whilst in the present work, performance has been checked for different cold mass ratios as well as inlet pressure values.The inlet pressure values are selected pertaining to common scenario in process industries.It is inferred from the results that the computational model is able to replicate the exergetic behaviour of vortex tube with good agreement.As hypothesized at the beginning of this research, cold mass ratio is found to be indeed an important parameter from both energy as well as exergy analysis point of view.The amount of inlet total exergy is 559 W at 200 kPa, 966 W at 300 kPa, 1352.71W at 400 kPa, 1538.86W at 486 kPa, 1732.29 W at 500 kPa and 2174.54W at 600 kPa inlet pressure.Maximum cold exergy efficiency of 27.77% and hot exergy efficiency of 39.39% is observed at inlet pressure of 600 kPa.Total exergy efficiency shows minimum value for cold mass ratios in the range of 0.4 to 0.6.Cold-end exergy efficiency is observed to be more affected due to inlet pressure than hot-end exergy efficiency.

Journal of Thermal Engineering
Openalex Percentile: Top 29%
Ranque-Hilsch vortex tube
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Computational investigation and exergy analysis of swirling flow in vortex tube — Hitesh R. Thakare · Journal of Thermal Engineering (2025) | TGRS Research Map | TGRS