Energy-Efficient Condition-Based Maintenance: A Smart Framework for Predictive Decision-Making in Industry 4.0

This study presents an energy-aware Condition-Based Maintenance (CBM) framework for an SKF 6205 bearing in a motor-driven system, integrating Industry 4.0 technologies. Real-time data from ESP32-based IoT sensors enabled degradation modeling using a Gamma process and evaluation of energy efficiency. The degradation index (Xt), derived from tri-axial RMS vibration, identified a failure threshold of 41.5 g·min, with a CBM trigger set at 75% (31.13 g·min). An Energy Efficiency Indicator (EEI), defined as the ratio of power input to incremental degradation, highlighted performance drops near failure, validating the thresholds. Remaining Useful Life (RUL) was estimated using Maximum Likelihood Estimation on Gamma distribution parameters (α = 16.61, β = 0.000286). The proposed approach links energy efficiency with wear progression, enabling accurate, sustainable maintenance decisions in smart manufacturing environments.

Authors

Publication Details

Journal
Journal of Information Systems Engineering & Management
Published
2024-12-30
DOI
https://doi.org/10.52783/jisem.v9i4s.12213
Citations
1
Primary Topic
Digital Transformation in Industry
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy-Efficient Condition-Based Maintenance: A Smart Framework for Predictive Decision-Making in Industry 4.0

S. C. Gujrathi
1 citations
Journal of Information Systems Engineering & Management
Digital Transformation in Industry
0.35
article

Energy-Efficient Condition-Based Maintenance: A Smart Framework for Predictive Decision-Making in Industry 4.0

S. C. Gujrathi
article en
1 citations

Abstract

This study presents an energy-aware Condition-Based Maintenance (CBM) framework for an SKF 6205 bearing in a motor-driven system, integrating Industry 4.0 technologies. Real-time data from ESP32-based IoT sensors enabled degradation modeling using a Gamma process and evaluation of energy efficiency. The degradation index (Xt), derived from tri-axial RMS vibration, identified a failure threshold of 41.5 g·min, with a CBM trigger set at 75% (31.13 g·min). An Energy Efficiency Indicator (EEI), defined as the ratio of power input to incremental degradation, highlighted performance drops near failure, validating the thresholds. Remaining Useful Life (RUL) was estimated using Maximum Likelihood Estimation on Gamma distribution parameters (α = 16.61, β = 0.000286). The proposed approach links energy efficiency with wear progression, enabling accurate, sustainable maintenance decisions in smart manufacturing environments.

Journal of Information Systems Engineering & ManagementVol. 9(4s)
Openalex Percentile: Top 30%
Digital Transformation in Industry
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.