[Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models].

<b>Objective:</b> To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options. <b>Methods:</b> One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared. <b>Results:</b> The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups (<i>P</i>>0.05). <b>Conclusions:</b> This <i>in vitro</i> experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2025-08-09
DOI
https://doi.org/10.3760/cma.j.cn112144-20241025-00401
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models].

Shenghui Yu, Qi Yan, Yangyu Zhao, Y L Wang et al.
PubMed
Dental Implant Techniques and Outcomes
article

[Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models].

Shenghui Yu, Qi Yan, Yangyu Zhao, Y L Wang, Yufeng Zhang, Yi-Xiang Wang
article en

Abstract

<b>Objective:</b> To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options. <b>Methods:</b> One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared. <b>Results:</b> The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups (<i>P</i>>0.05). <b>Conclusions:</b> This <i>in vitro</i> experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.

PubMedVol. 60(8)
Wuhan University (CN)
Openalex Percentile: Top 73%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.