Analysis of Electrical Energy Management Performance in Asri Hotel Building

The Energy Efficiency Index (EEI) records a building's performance and provides a baseline for energy consumption. Analyzing a power system using EEI involves total energy consumption, electricity consumption for each zone, and energy consumption distribution. This study aims to determine the electrical load profile and building profile of electrical energy consumption at Hotel Asri, analyze the performance of electrical energy use, and provide optimization conclusions. The electrical load profile includes installed loads (computers, TVs, hairdryers, refrigerators), cooling loads (Air Conditioning), lighting loads, and other loads (pumps, water filters). Hotel Asri's building area is 3446 m2, with an average total electrical energy consumption of 39.98967 kWh per year. After measuring Light Intensity and calculating installed and cooling loads, the IKE calculation for buildings with air conditioning is 7.8 kWh / m2 per month (highly efficient) and without air conditioning is 1.19 kWh / m2 per month (highly efficient). The IKE of the entire Asri Hotel building is 139,225 kWh/m2 per year, below the IKE target for hotels. Although Hotel Asri's IKE is highly efficient based on Indonesian building standards, many lighting measurements do not comply with the Indonesian National Standard for artificial lighting (SNI 03-2496-2001).

Authors

Institutions

Publication Details

Journal
Journal FORTEI-JEERI
Published
2025-05-31
DOI
https://doi.org/10.46962/forteijeeri.v6i1.27
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Electrical Energy Management Performance in Asri Hotel Building

Asep Andang, Nurul Hiron, Sari Wahyuningsih
Journal FORTEI-JEERI
Engineering and Technology Innovations
article

Analysis of Electrical Energy Management Performance in Asri Hotel Building

Asep Andang, Nurul Hiron, Sari Wahyuningsih
article en

Abstract

The Energy Efficiency Index (EEI) records a building's performance and provides a baseline for energy consumption. Analyzing a power system using EEI involves total energy consumption, electricity consumption for each zone, and energy consumption distribution. This study aims to determine the electrical load profile and building profile of electrical energy consumption at Hotel Asri, analyze the performance of electrical energy use, and provide optimization conclusions. The electrical load profile includes installed loads (computers, TVs, hairdryers, refrigerators), cooling loads (Air Conditioning), lighting loads, and other loads (pumps, water filters). Hotel Asri's building area is 3446 m2, with an average total electrical energy consumption of 39.98967 kWh per year. After measuring Light Intensity and calculating installed and cooling loads, the IKE calculation for buildings with air conditioning is 7.8 kWh / m2 per month (highly efficient) and without air conditioning is 1.19 kWh / m2 per month (highly efficient). The IKE of the entire Asri Hotel building is 139,225 kWh/m2 per year, below the IKE target for hotels. Although Hotel Asri's IKE is highly efficient based on Indonesian building standards, many lighting measurements do not comply with the Indonesian National Standard for artificial lighting (SNI 03-2496-2001).

Journal FORTEI-JEERIVol. 6(1)
Siliwangi University (ID)
Openalex Percentile: Top 83%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.