Impact of Tropical Environmental Conditions on Mechanical Cooling Tower Performance: A Case Study at PT. XYZ

Indonesia's tropical climate, characterized by high ambient temperatures, intense humidity, and frequent rainfall, presents significant challenges for industrial cooling systems. This research investigates how tropical climate conditions influence the operational performance of a mechanical cooling tower installed at PT. XYZ, located in Cileungsi, West Java, Indonesia. The research offers valuable insights into energy optimization and operational planning under varying weather scenarios. Data collection involved real-time measurements under nine combinations of weather and time conditions (sunny, cloudy, rainy; morning, noon, afternoon), using thermocouples, hygrometers, and an ESP32 microcontroller. Key variables observed include ambient temperature, incoming water temperature, outgoing water temperature, relative humidity, and wet bulb temperature. Multiple linear regression was employed for analysis, supported by correlation analysis, t-tests, and F-tests. The model achieved a high determination coefficient (R²) of 80%, indicating strong predictive accuracy. Partial R² analysis revealed that the outgoing water temperature contributed 77% to the variation in cooling tower efficiency, followed by ambient temperature at 65%, incoming water temperature at 54%, and relative humidity at 36%. The highest efficiency, 67%, was recorded during sunny mornings, while the lowest, 42%, occurred at rainy noon. These findings confirm that tropical environmental factors have a significant and quantifiable impact on cooling tower performance. The results are expected to support the development of adaptive and efficient energy strategies in tropical industrial contexts.

Authors

Institutions

Publication Details

Journal
Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)
Published
2025-07-30
DOI
https://doi.org/10.36842/jomase.v69i2.540
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Tropical Environmental Conditions on Mechanical Cooling Tower Performance: A Case Study at PT. XYZ

Fahrudin Fahrudin, Damora Rhakasywi, Eko Prasetyo
Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)
Adsorption and Cooling Systems
article

Impact of Tropical Environmental Conditions on Mechanical Cooling Tower Performance: A Case Study at PT. XYZ

Fahrudin Fahrudin, Damora Rhakasywi, Eko Prasetyo
article en

Abstract

Indonesia's tropical climate, characterized by high ambient temperatures, intense humidity, and frequent rainfall, presents significant challenges for industrial cooling systems. This research investigates how tropical climate conditions influence the operational performance of a mechanical cooling tower installed at PT. XYZ, located in Cileungsi, West Java, Indonesia. The research offers valuable insights into energy optimization and operational planning under varying weather scenarios. Data collection involved real-time measurements under nine combinations of weather and time conditions (sunny, cloudy, rainy; morning, noon, afternoon), using thermocouples, hygrometers, and an ESP32 microcontroller. Key variables observed include ambient temperature, incoming water temperature, outgoing water temperature, relative humidity, and wet bulb temperature. Multiple linear regression was employed for analysis, supported by correlation analysis, t-tests, and F-tests. The model achieved a high determination coefficient (R²) of 80%, indicating strong predictive accuracy. Partial R² analysis revealed that the outgoing water temperature contributed 77% to the variation in cooling tower efficiency, followed by ambient temperature at 65%, incoming water temperature at 54%, and relative humidity at 36%. The highest efficiency, 67%, was recorded during sunny mornings, while the lowest, 42%, occurred at rainy noon. These findings confirm that tropical environmental factors have a significant and quantifiable impact on cooling tower performance. The results are expected to support the development of adaptive and efficient energy strategies in tropical industrial contexts.

Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)Vol. 69(2)
University of Pembangunan Nasional Veteran Jawa Timur (ID), Universitas Pembangunan Nasional Veteran Jakarta (ID)
Openalex Percentile: Top 82%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.