Study Analysis of Three Phase Induction Motor Starting Using ETAP at PLN ULPL Indralaya, South Sumatera

Steam Generator of Electricity Power Plant at PT. PLN (Persero) UPDK Keramasan of ULPL Indralaya, South Sumatra Area. This power plant has 3-phase induction motors, which are the most commonly used motors because of their reliability. The 3-phase motor is directly connected to the supply at a high starting current of around 5 to 7 times the motor rating current (nominal current). This large starting current can cause a considerable voltage drop on the supply line, thus affecting other loads connected to the supply line. Because the large current flows for a long time, it causes the motor to heat up, which will damage the insulation. Therefore, when starting the motor, the motor bus voltage must be kept at around 80% of the voltage rating. This study investigates whether the motor could start successfully under the operating conditions. We used ETAP software to simulate motor starting and also analyze these motors is to obtain the values of starting current, starting torque, and voltage drop from the results of using VFD (variable frequency drive) on two motor units in LV Switchgear SUS-1 whose previous existing conditions were using DOL (direct on line). A result of our studies, we found that the system can still maintain a bus voltage of 99.94%, a small starting current when starting the motor of 0% FLA (1 second), and reaches 99% FLA (4 seconds) with a starting torque of 54% & 57% of the load torque.

Authors

Institutions

Publication Details

Journal
Energy - Jurnal Ilmiah Ilmu-Ilmu Teknik
Published
2025-05-31
DOI
https://doi.org/10.51747/energy.v15i1.1514
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study Analysis of Three Phase Induction Motor Starting Using ETAP at PLN ULPL Indralaya, South Sumatera

Thriskadewi Umi Rasyda, Letifa Shintawaty
Energy - Jurnal Ilmiah Ilmu-Ilmu Teknik
Electric Motor Design and Analysis
article

Study Analysis of Three Phase Induction Motor Starting Using ETAP at PLN ULPL Indralaya, South Sumatera

Thriskadewi Umi Rasyda, Letifa Shintawaty
article en

Abstract

Steam Generator of Electricity Power Plant at PT. PLN (Persero) UPDK Keramasan of ULPL Indralaya, South Sumatra Area. This power plant has 3-phase induction motors, which are the most commonly used motors because of their reliability. The 3-phase motor is directly connected to the supply at a high starting current of around 5 to 7 times the motor rating current (nominal current). This large starting current can cause a considerable voltage drop on the supply line, thus affecting other loads connected to the supply line. Because the large current flows for a long time, it causes the motor to heat up, which will damage the insulation. Therefore, when starting the motor, the motor bus voltage must be kept at around 80% of the voltage rating. This study investigates whether the motor could start successfully under the operating conditions. We used ETAP software to simulate motor starting and also analyze these motors is to obtain the values of starting current, starting torque, and voltage drop from the results of using VFD (variable frequency drive) on two motor units in LV Switchgear SUS-1 whose previous existing conditions were using DOL (direct on line). A result of our studies, we found that the system can still maintain a bus voltage of 99.94%, a small starting current when starting the motor of 0% FLA (1 second), and reaches 99% FLA (4 seconds) with a starting torque of 54% & 57% of the load torque.

Energy - Jurnal Ilmiah Ilmu-Ilmu TeknikVol. 15(1)
Universitas Tridinanti Palembang (ID)
Openalex Percentile: Top 83%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.