Improving Outcomes of Single-Sided Deaf Cochlear Implant Users by Reducing Interaural Frequency and Loudness Mismatches through Device Programming

The study aimed to improve outcomes in Nucleus cochlear implant (CI) recipients with single-sided deafness (SSD) by reducing interaural frequency and loudness mismatches through device programming. In Experiment 1a, a modified frequency allocation table (FAT) was created to better match the tonotopicity of the contralateral ear and reduce interaural frequency mismatch. Twenty experienced SSD-CI users completed localization and speech recognition tests with their everyday FAT. Tests were repeated after 6 weeks' use of the modified FAT. Participants compared both FATs for 2 weeks before being tested again with each. For 10 newly implanted SSD-CI recipients (Experiment 1b), Group A was programmed with the manufacturer's default FAT and Group B with the modified FAT at activation. Speech recognition and localization were completed, after 6 weeks' use of each FAT. Participants then compared both FATs before testing with each. In Experiment 2, 15 experienced SSD-CI users were evaluated with their everyday program and a modified loudness program, which was created to obtain audibility of ∼20 dB HL from 0.25 to 6 kHz and balanced loudness between ears. Three test sessions occurred, resembling Experiment 1a. Experienced participants in Experiments 1a and 2 showed significant improvement in one speech-in-noise task with a modified program compared to the everyday program. Newly implanted recipients showed no significant difference in results between FATs. Results indicate that modified programs, created to reduce interaural mismatches, may improve outcomes. The first month after activation might be too early to compare FATs as SSD-CI recipients are adjusting to electric hearing.

Authors

Institutions

Publication Details

Journal
Trends in Hearing
Published
2025-07-30
DOI
https://doi.org/10.1177/23312165251359415
Citations
1
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Outcomes of Single-Sided Deaf Cochlear Implant Users by Reducing Interaural Frequency and Loudness Mismatches through Device Programming

Noel Dwyer, Jill B. Firszt, Rosalie M. Uchanski, Laura K. Holden et al.
1 citations
Trends in Hearing
Hearing Loss and Rehabilitation
1.43
article

Improving Outcomes of Single-Sided Deaf Cochlear Implant Users by Reducing Interaural Frequency and Loudness Mismatches through Device Programming

Noel Dwyer, Jill B. Firszt, Rosalie M. Uchanski, Laura K. Holden, Timothy A. Holden, Ruth M Reeder
article en
1 citations

Abstract

The study aimed to improve outcomes in Nucleus cochlear implant (CI) recipients with single-sided deafness (SSD) by reducing interaural frequency and loudness mismatches through device programming. In Experiment 1a, a modified frequency allocation table (FAT) was created to better match the tonotopicity of the contralateral ear and reduce interaural frequency mismatch. Twenty experienced SSD-CI users completed localization and speech recognition tests with their everyday FAT. Tests were repeated after 6 weeks' use of the modified FAT. Participants compared both FATs for 2 weeks before being tested again with each. For 10 newly implanted SSD-CI recipients (Experiment 1b), Group A was programmed with the manufacturer's default FAT and Group B with the modified FAT at activation. Speech recognition and localization were completed, after 6 weeks' use of each FAT. Participants then compared both FATs before testing with each. In Experiment 2, 15 experienced SSD-CI users were evaluated with their everyday program and a modified loudness program, which was created to obtain audibility of ∼20 dB HL from 0.25 to 6 kHz and balanced loudness between ears. Three test sessions occurred, resembling Experiment 1a. Experienced participants in Experiments 1a and 2 showed significant improvement in one speech-in-noise task with a modified program compared to the everyday program. Newly implanted recipients showed no significant difference in results between FATs. Results indicate that modified programs, created to reduce interaural mismatches, may improve outcomes. The first month after activation might be too early to compare FATs as SSD-CI recipients are adjusting to electric hearing.

Trends in HearingVol. 29
Washington University in St. Louis (US)
Quality Education
Openalex Percentile: Top 17%
Hearing Loss and Rehabilitation
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Outcomes of Single-Sided Deaf Cochlear Implant Users by Reducing Interaural Frequency and Loudness Mismatches through Device Programming — Noel Dwyer, Jill B. Firszt, et al. · Trends in Hearing (2025) | TGRS Research Map | TGRS