High Pressure Transfer Pump Efficiency Calculation Before And After Reverse Engineering at PLTGU XYZ

Steam Gas Power Plant (PLTGU) is a power plant that uses gas as fuel and reuses exhaust gas from the gas turbine to heat the pipes in the HRSG (Heat Recovery Steam Generator) to produce steam and rotate the steam turbine. PLTGU XYZ is a Gas and Steam Power Plant which has 2,154 MW. One of the important components used in PLTGU is the high-pressure transfer pump. A high-pressure transfer pump is a pump that functions to move water from the low-pressure drum through the high pressure economizer to the high pressure drum, using an automatic system. The type of high-pressure transfer pump at PLTGU XYZ is Type MC100-300/9. To maintain the efficiency of the high-pressure transfer pump, components need to be maintained or replaced. high pressure transfer pump components have been replaced on the pump shaft using the reverse engineering method. Before reverse engineering the large pump shaft the efficiency was 66%, and after reverse engineering the large pump shaft the efficiency was 63%, so the comparison of pump efficiency before and after reverse engineering the pump shaft was 3%.

Authors

Publication Details

Journal
Teknobiz Jurnal Ilmiah Program Studi Magister Teknik Mesin
Published
2025-03-24
DOI
https://doi.org/10.35814/teknobiz.v15i1.8549
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Pressure Transfer Pump Efficiency Calculation Before And After Reverse Engineering at PLTGU XYZ

Istianto Budhi Rahardja, Eko Sulistiyo, Bambang Setiadi, Josua Uli Syahputra Sitompul
Teknobiz Jurnal Ilmiah Program Studi Magister Teknik Mesin
Hydraulic and Pneumatic Systems
article

High Pressure Transfer Pump Efficiency Calculation Before And After Reverse Engineering at PLTGU XYZ

Istianto Budhi Rahardja, Eko Sulistiyo, Bambang Setiadi, Josua Uli Syahputra Sitompul
article en

Abstract

Steam Gas Power Plant (PLTGU) is a power plant that uses gas as fuel and reuses exhaust gas from the gas turbine to heat the pipes in the HRSG (Heat Recovery Steam Generator) to produce steam and rotate the steam turbine. PLTGU XYZ is a Gas and Steam Power Plant which has 2,154 MW. One of the important components used in PLTGU is the high-pressure transfer pump. A high-pressure transfer pump is a pump that functions to move water from the low-pressure drum through the high pressure economizer to the high pressure drum, using an automatic system. The type of high-pressure transfer pump at PLTGU XYZ is Type MC100-300/9. To maintain the efficiency of the high-pressure transfer pump, components need to be maintained or replaced. high pressure transfer pump components have been replaced on the pump shaft using the reverse engineering method. Before reverse engineering the large pump shaft the efficiency was 66%, and after reverse engineering the large pump shaft the efficiency was 63%, so the comparison of pump efficiency before and after reverse engineering the pump shaft was 3%.

Teknobiz Jurnal Ilmiah Program Studi Magister Teknik MesinVol. 15(1)
Openalex Percentile: Top 82%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High Pressure Transfer Pump Efficiency Calculation Before And After Reverse Engineering at PLTGU XYZ — Istianto Budhi Rahardja, Eko Sulistiyo, et al. · Teknobiz Jurnal Ilmiah Program Studi Magister Teknik Mesin (2025) | TGRS Research Map | TGRS