An Integrated Pressure-Volume Loop and Pulmonary Artery Catheter

An admittance technology (AT) pulmonary artery catheter was developed to measure instantaneous right ventricular (RV) pressure-volume loops. Admittance RV volumes were validated in vivo through 10 swine subjected to positive and negative hemodynamic perturbations compared with magnetic resonance imaging and ex vivo RV foam casts. Finite element analysis demonstrated the AT electric field was confined to RV blood volume. RV pressure-volume loops demonstrated anticipated changes in all hemodynamics, and end-diastolic volumes were equal to magnetic resonance imaging and foam casts (P = NS). Increasing RV end-diastolic volumes in response to acute cardiac injury were also measured (P < 0.001). We report validating an AT pulmonary artery catheter in a swine model.

Authors

Institutions

Publication Details

Journal
JACC Basic to Translational Science
Published
2025-07-30
DOI
https://doi.org/10.1016/j.jacbts.2025.101326
Citations
1
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrated Pressure-Volume Loop and Pulmonary Artery Catheter

Alexander J. Moody, Joel Michalek, Drew Nolen, Aleksandra Gruslova et al.
1 citations
JACC Basic to Translational Science
Hemodynamic Monitoring and Therapy
2.01
article

An Integrated Pressure-Volume Loop and Pulmonary Artery Catheter

Alexander J. Moody, Joel Michalek, Drew Nolen, Aleksandra Gruslova, Clay Heighten, Vivek Jani, Mohammed Aslam, Luis A Diaz Sanmartin, Fawaz Alenezi, Marc D. Feldman, James John Elliott, J. W. Valvano
article en
1 citations

Abstract

An admittance technology (AT) pulmonary artery catheter was developed to measure instantaneous right ventricular (RV) pressure-volume loops. Admittance RV volumes were validated in vivo through 10 swine subjected to positive and negative hemodynamic perturbations compared with magnetic resonance imaging and ex vivo RV foam casts. Finite element analysis demonstrated the AT electric field was confined to RV blood volume. RV pressure-volume loops demonstrated anticipated changes in all hemodynamics, and end-diastolic volumes were equal to magnetic resonance imaging and foam casts (P = NS). Increasing RV end-diastolic volumes in response to acute cardiac injury were also measured (P < 0.001). We report validating an AT pulmonary artery catheter in a swine model.

JACC Basic to Translational ScienceVol. 10(8)
Johns Hopkins University (US), The University of Texas at San Antonio Health Science Center (US), Johns Hopkins Medicine (US), Duke Medical Center (US), The University of Texas at San Antonio (US), The University of Texas at Austin (US)
University of Texas Health Science Center at San Antonio, National Heart, Lung, and Blood Institute, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 13%
Hemodynamic Monitoring and Therapy
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Integrated Pressure-Volume Loop and Pulmonary Artery Catheter — Alexander J. Moody, Joel Michalek, et al. · JACC Basic to Translational Science (2025) | TGRS Research Map | TGRS