An Energy-Aware, Self-Adaptive, Battery-Free Smart Wristband for Long-Term Health Monitoring

Continuous monitoring of physiological parameters, including heart rate and oxygen saturation, is important in healthcare applications. Modern wearables are expected to support wireless connectivity, be small and lightweight, and offer long-term use. These features introduce challenges in power consumption and management. As a result, battery-powered wearables often face trade-offs between size, energy storage, performance, and operating time. This research presents a self-sustainable, battery-free smart wristband for continuous heart rate monitoring. The wristband extends operational life by integrating solar energy harvesting with supercapacitor technology in an environmentally sustainable design. Power consumption is minimized through onboard processing, which reduces inefficient data transmission, and adaptive sensor sampling, which dynamically allocates energy based on heart rate, supercapacitor voltage, and harvesting conditions. Benefiting from hardware and software co-design, the proposed wearable device achieves self-sustainability at a sensor sampling rate of 50 Hz with only 1.45 hours of indoor light exposure (1000 lux) per day and at 200 Hz with 4.74 hours. The in-field experiments show that onboard processing reduces Bluetooth Low Energy (BLE) data transmission to essential information, saving about 2 J of energy. The system shortens supercapacitor charging time by 17 minutes per hour through its ability to automatically reduce the sampling frequency from 200 Hz to 50 Hz when harvesting energy is scarce. The proposed system can even operate effectively in around 200 lux of light, equivalent to a dimly lit living room. These results underscore the system’s ability to dynamically balance power-performance trade-offs, offering a promising long-term solution for continuous health monitoring in various environments.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3593936
Citations
1
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Energy-Aware, Self-Adaptive, Battery-Free Smart Wristband for Long-Term Health Monitoring

Esther Rodriguez–Villegas, Shihong Chen
1 citations
IEEE Access
Wireless Body Area Networks
0.67
article

An Energy-Aware, Self-Adaptive, Battery-Free Smart Wristband for Long-Term Health Monitoring

Esther Rodriguez–Villegas, Shihong Chen
article en
1 citations

Abstract

Continuous monitoring of physiological parameters, including heart rate and oxygen saturation, is important in healthcare applications. Modern wearables are expected to support wireless connectivity, be small and lightweight, and offer long-term use. These features introduce challenges in power consumption and management. As a result, battery-powered wearables often face trade-offs between size, energy storage, performance, and operating time. This research presents a self-sustainable, battery-free smart wristband for continuous heart rate monitoring. The wristband extends operational life by integrating solar energy harvesting with supercapacitor technology in an environmentally sustainable design. Power consumption is minimized through onboard processing, which reduces inefficient data transmission, and adaptive sensor sampling, which dynamically allocates energy based on heart rate, supercapacitor voltage, and harvesting conditions. Benefiting from hardware and software co-design, the proposed wearable device achieves self-sustainability at a sensor sampling rate of 50 Hz with only 1.45 hours of indoor light exposure (1000 lux) per day and at 200 Hz with 4.74 hours. The in-field experiments show that onboard processing reduces Bluetooth Low Energy (BLE) data transmission to essential information, saving about 2 J of energy. The system shortens supercapacitor charging time by 17 minutes per hour through its ability to automatically reduce the sampling frequency from 200 Hz to 50 Hz when harvesting energy is scarce. The proposed system can even operate effectively in around 200 lux of light, equivalent to a dimly lit living room. These results underscore the system’s ability to dynamically balance power-performance trade-offs, offering a promising long-term solution for continuous health monitoring in various environments.

IEEE AccessVol. 13
Imperial College London (GB)
European Research Council
Affordable and clean energy
Openalex Percentile: Top 29%
Wireless Body Area Networks
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.