Experiment of Dielectric Frequency Response for Aged ZnO Surge Arrester

Condition-based monitoring of surge arresters has gained increasing attention in modern power system asset management, especially for medium-voltage equipment. This paper presents an investigation into the dielectric frequency response (DFR) analysis technique as a diagnostic method to evaluate aging and unhealthy conditions in <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$21-\text{kV}$</tex> metal oxide surge arresters (MOSA). Four types of simulated defects, excessive number of lightning current stress, cracking, moisture ingress, and tracking, were introduced to represent common field failures. The DFR technique enables frequencydomain interpretation of dielectric properties, providing insight into insulation behavior over a wide frequency range. The test results show a significant variation in capacitance and dissipation factor corresponding to different defect types. Among these, moisture ingress exhibited the most severe deterioration. The findings suggest that DFR is a viable offline diagnostic method that can support preventive maintenance strategies for high-voltage surge arresters.

Authors

Institutions

Publication Details

Published
2025-05-06
DOI
https://doi.org/10.1109/iceast64767.2025.11088192
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experiment of Dielectric Frequency Response for Aged ZnO Surge Arrester

Winai Methavithit, Matthieu Zinck, Pittaya Pannil, Norasage Pattanadech et al.
High voltage insulation and dielectric phenomena
article

Experiment of Dielectric Frequency Response for Aged ZnO Surge Arrester

Winai Methavithit, Matthieu Zinck, Pittaya Pannil, Norasage Pattanadech, Chaitawat Chuayin, Siwakorn Jeenmuang, Chanin Bunlaksananusorn, Phitthaya Aiamrungruang
article en

Abstract

Condition-based monitoring of surge arresters has gained increasing attention in modern power system asset management, especially for medium-voltage equipment. This paper presents an investigation into the dielectric frequency response (DFR) analysis technique as a diagnostic method to evaluate aging and unhealthy conditions in <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$21-\text{kV}$</tex> metal oxide surge arresters (MOSA). Four types of simulated defects, excessive number of lightning current stress, cracking, moisture ingress, and tracking, were introduced to represent common field failures. The DFR technique enables frequencydomain interpretation of dielectric properties, providing insight into insulation behavior over a wide frequency range. The test results show a significant variation in capacitance and dissipation factor corresponding to different defect types. Among these, moisture ingress exhibited the most severe deterioration. The findings suggest that DFR is a viable offline diagnostic method that can support preventive maintenance strategies for high-voltage surge arresters.

Rajamangala University of Technology Krungthep (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 87%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.