Sensor Technology NoiSens for Noise Detection on Construction Sites

Anthropogenic activities can lead to environmental contamination and violations of the quality of the working environment, which has a negative impact on human health. Increasing construction works create noise that can have a harmful effect on human health. Standard methods for measuring noise are generally accepted, but due to certain limitations, there is a need for the development of new alternative methods, such as sensor technologies. This study compares laboratory and field measurements with the sensor device (NoiSens), and based on the results of the independent t-test, it can be concluded that there is no significant difference (t=-1.747, p=0.081) in the measured noise level. The NoiSens device proved to be reliable and efficient for measuring noise levels at construction sites, demonstrating that it can replace standard methods for noise measurement.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.23919/splitech65624.2025.11091705
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensor Technology NoiSens for Noise Detection on Construction Sites

Ivana Krtolica, Boris Obrovski, Vladimir Rajs, Miljan Šunjević
Flow Measurement and Analysis
article

Sensor Technology NoiSens for Noise Detection on Construction Sites

Ivana Krtolica, Boris Obrovski, Vladimir Rajs, Miljan Šunjević
article en

Abstract

Anthropogenic activities can lead to environmental contamination and violations of the quality of the working environment, which has a negative impact on human health. Increasing construction works create noise that can have a harmful effect on human health. Standard methods for measuring noise are generally accepted, but due to certain limitations, there is a need for the development of new alternative methods, such as sensor technologies. This study compares laboratory and field measurements with the sensor device (NoiSens), and based on the results of the independent t-test, it can be concluded that there is no significant difference (t=-1.747, p=0.081) in the measured noise level. The NoiSens device proved to be reliable and efficient for measuring noise levels at construction sites, demonstrating that it can replace standard methods for noise measurement.

University of Novi Sad (RS)
Openalex Percentile: Top 79%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensor Technology NoiSens for Noise Detection on Construction Sites — Ivana Krtolica, Boris Obrovski, et al. · (2025) | TGRS Research Map | TGRS