Dosimetric Analysis of Human Exposure in Near-Field Wireless Power Transfer Systems: A Comparison of Analytical and Numerical Methods

This paper investigates the effects of high-frequency radio waves on human exposure in wireless power transfer systems health impacts due to high-frequency radiation exposure, particularly examining induced electric fields, transmitted power density and specific absorption rates at frequencies of 6.78 MHz and 86.33 MHz. Comparisons were made between a simplified cylindrical model and a realistic human body model. The analytical approach assumes a sinusoidal current distribution along the cylinder. Numerical simulations, performed with the commercial software FEKO, validated the analytical findings presented. The results indicate that the analytical model shows good agreement with the numerical simulations, with differences generally within 10% for average specific absorption rate values. However, discrepancies are more pronounced in localized regions of high field intensity and when using the realistic human model. This consistency suggests that analytical methods offer a reliable, and rapid estimation for assessing compliance with exposure standards.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.23919/splitech65624.2025.11091740
Primary Topic
Energy Harvesting in Wireless Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Analysis of Human Exposure in Near-Field Wireless Power Transfer Systems: A Comparison of Analytical and Numerical Methods

Petra Rašić, Zoran Blažević, Dragan Poljak, Maja Škiljo
Energy Harvesting in Wireless Networks
article

Dosimetric Analysis of Human Exposure in Near-Field Wireless Power Transfer Systems: A Comparison of Analytical and Numerical Methods

Petra Rašić, Zoran Blažević, Dragan Poljak, Maja Škiljo
article en

Abstract

This paper investigates the effects of high-frequency radio waves on human exposure in wireless power transfer systems health impacts due to high-frequency radiation exposure, particularly examining induced electric fields, transmitted power density and specific absorption rates at frequencies of 6.78 MHz and 86.33 MHz. Comparisons were made between a simplified cylindrical model and a realistic human body model. The analytical approach assumes a sinusoidal current distribution along the cylinder. Numerical simulations, performed with the commercial software FEKO, validated the analytical findings presented. The results indicate that the analytical model shows good agreement with the numerical simulations, with differences generally within 10% for average specific absorption rate values. However, discrepancies are more pronounced in localized regions of high field intensity and when using the realistic human model. This consistency suggests that analytical methods offer a reliable, and rapid estimation for assessing compliance with exposure standards.

University of Split (HR)
Openalex Percentile: Top 83%
Energy Harvesting in Wireless Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.