Super-Resolution Reconstruction of OCTA Via Multi-Field-of-View Representation Learning

High-resolution Optical Coherence Tomography Angiography (OCTA) images are essential for morphological analysis and biomarker measurement of the retinal vasculature. They can also provide underlying biomarkers for the accurate analysis of eye-related diseases. The trade-off between the high resolution (HR) and large scanning field-of-view (FOV) is a long-standing problem for OCTA image instrument. A large FOV image provides more retinal information with shorter acquisition time but often suffers from low resolution (LR), high scatter noise, and poor vascular contrast. In order to obtain HR OCTA images with larger FOV, we propose a novel self-similar dynamic domain adaptation network based on cross-field-of-view representation learning. The network enables LR images (i.e., $6\times \text{6}~\text{mm}^{2}$) to learn HR image (i.e., $3\times \text{3}~\text{mm}^{2}$) feature representations specialized for OCTA by constructing feature mapping relations for cross-field-of-view OCTA scans. To be specific, a multiple random degradation model is proposed on HR images to generate various synthetic LR images. Further, we propose a dynamic domain adaptation framework that prompts feature dynamic alignment of the LR image reconstruction results with those of synthetic LR images. Finally, a novel self-similar supervision loss is proposed to optimize the reconstruction results from LR to HR by exploiting the similarity between vessels in different regions. Experimental results on three OCTA datasets show that the proposed method surpasses existing state-of-the-art ones, significantly enhancing retinal structure segmentation and disease classification. Our OCTA dataset (the first dataset in this research area with paired $3\times 3$ and $6\times \text{6}~\text{mm}^{2}$ OCTA images) and code are publicly available.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3593149
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolution Reconstruction of OCTA Via Multi-Field-of-View Representation Learning

Shaoyi Leng, Huazhu Fu, Yonghuai Liu, Yitian Zhao et al.
IEEE Journal of Biomedical and Health Informatics
Optical Coherence Tomography Applications
article

Super-Resolution Reconstruction of OCTA Via Multi-Field-of-View Representation Learning

Shaoyi Leng, Huazhu Fu, Yonghuai Liu, Yitian Zhao, Yanda Meng, Quanyong Yi, Yalin Zheng, Jiong Zhang, Yue Liu, Jingfeng Zhang, Huaying Hao
article en

Abstract

High-resolution Optical Coherence Tomography Angiography (OCTA) images are essential for morphological analysis and biomarker measurement of the retinal vasculature. They can also provide underlying biomarkers for the accurate analysis of eye-related diseases. The trade-off between the high resolution (HR) and large scanning field-of-view (FOV) is a long-standing problem for OCTA image instrument. A large FOV image provides more retinal information with shorter acquisition time but often suffers from low resolution (LR), high scatter noise, and poor vascular contrast. In order to obtain HR OCTA images with larger FOV, we propose a novel self-similar dynamic domain adaptation network based on cross-field-of-view representation learning. The network enables LR images (i.e., $6\times \text{6}~\text{mm}^{2}$) to learn HR image (i.e., $3\times \text{3}~\text{mm}^{2}$) feature representations specialized for OCTA by constructing feature mapping relations for cross-field-of-view OCTA scans. To be specific, a multiple random degradation model is proposed on HR images to generate various synthetic LR images. Further, we propose a dynamic domain adaptation framework that prompts feature dynamic alignment of the LR image reconstruction results with those of synthetic LR images. Finally, a novel self-similar supervision loss is proposed to optimize the reconstruction results from LR to HR by exploiting the similarity between vessels in different regions. Experimental results on three OCTA datasets show that the proposed method surpasses existing state-of-the-art ones, significantly enhancing retinal structure segmentation and disease classification. Our OCTA dataset (the first dataset in this research area with paired $3\times 3$ and $6\times \text{6}~\text{mm}^{2}$ OCTA images) and code are publicly available.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Agency for Science, Technology and Research (SG), Beijing Institute of Technology (CN), University of Liverpool (GB), Edge Hill University (GB), Chinese Academy of Sciences (CN), Wenzhou Medical University (CN), Institute of High Performance Computing (SG), Affiliated Eye Hospital of Wenzhou Medical College (CN), Ningbo No. 2 Hospital (CN), Ningbo Institute of Industrial Technology (CN)
Openalex Percentile: Top 83%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.