In Situ Synchronous Measurement of Low-Frequency Magnetic Field Fluctuation Based on Temporal Differencing in Atomic Comagnetometer

Fluctuations in transverse low-frequency magnetic fields significantly impact the long-term stability of atomic comagnetometers (ACMs). Due to the strong coupling between magnetic fields and gyro signals, conventional evaluation approaches are typically limited to offline analysis. To address this challenge, this paper proposes a temporal differencing (TD) technique combined with baseline alignment (BA), leveraging quantum spin dynamics under longitudinal magnetic field modulation to construct a differential response model. The TD approach compresses the response time scale of the system, thereby enhancing immunity to multi-source disturbances. Meanwhile, BA enables the synchronous acquisition of magnetic field fluctuations and gyro signals, facilitating real-time evaluation. Experimental results show that, under disturbances such as probe light power, pump light power, and vapor cell temperature, the proposed TD method achieves a suppression of at least 56.5% compared to INSR and a suppression of at least 65.6% compared to the Z-mode method, covering all components of the transverse field. Furthermore, the equivalent angular velocity deviations caused by transverse field fluctuations are quantified as 6.9×10-3 deg/h along the x-axis and 2.9×10-3 deg/h along the y-axis, contributing 28.4% and 11.9% to the degradation of the long-term stability of the ACM, respectively. These results demonstrate that the proposed method enables accurate and reliable in-situ evaluation of transverse magnetic field disturbances and offers practical insights for enhancing the robustness of ACM systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3593551
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Situ Synchronous Measurement of Low-Frequency Magnetic Field Fluctuation Based on Temporal Differencing in Atomic Comagnetometer

Zhihong Wu, Hongyu Pei, Xusheng Lei, Haoying Pang et al.
1 links
IEEE Transactions on Instrumentation and Measurement
Atomic and Subatomic Physics Research
article

In Situ Synchronous Measurement of Low-Frequency Magnetic Field Fluctuation Based on Temporal Differencing in Atomic Comagnetometer

Zhihong Wu, Hongyu Pei, Xusheng Lei, Haoying Pang, Yizhe Zhou, Jiaxin Liu, Yu Yuan
article en

Abstract

Fluctuations in transverse low-frequency magnetic fields significantly impact the long-term stability of atomic comagnetometers (ACMs). Due to the strong coupling between magnetic fields and gyro signals, conventional evaluation approaches are typically limited to offline analysis. To address this challenge, this paper proposes a temporal differencing (TD) technique combined with baseline alignment (BA), leveraging quantum spin dynamics under longitudinal magnetic field modulation to construct a differential response model. The TD approach compresses the response time scale of the system, thereby enhancing immunity to multi-source disturbances. Meanwhile, BA enables the synchronous acquisition of magnetic field fluctuations and gyro signals, facilitating real-time evaluation. Experimental results show that, under disturbances such as probe light power, pump light power, and vapor cell temperature, the proposed TD method achieves a suppression of at least 56.5% compared to INSR and a suppression of at least 65.6% compared to the Z-mode method, covering all components of the transverse field. Furthermore, the equivalent angular velocity deviations caused by transverse field fluctuations are quantified as 6.9×10-3 deg/h along the x-axis and 2.9×10-3 deg/h along the y-axis, contributing 28.4% and 11.9% to the degradation of the long-term stability of the ACM, respectively. These results demonstrate that the proposed method enables accurate and reliable in-situ evaluation of transverse magnetic field disturbances and offers practical insights for enhancing the robustness of ACM systems.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Beihang University (CN)
China Postdoctoral Science Foundation, Natural Science Foundation of Beijing Municipality
Openalex Percentile: Top 86%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.