System-Level Analysis of LED Retrofit Solutions for T8 Fluorescent Tubes: Harmonic Emissions, Photometric Impacts, and Compliance Considerations

This study investigates the harmonic emissions, photometric performance, and technoeconomic implications of retrofitting T8 fluorescent tubes with LED alternatives under various ballast configurations. Experimental results reveal that while legacy fluorescent installations—whether magnetic or electronic—generally comply with EN IEC 61000-3-2 harmonic limits, most retrofit LED tube scenarios do not. The lack or ineffectiveness of power factor correction circuits in low-power LED tubes is identified as a key contributor to non-compliance. Moreover, the presence of magnetic ballasts introduces unpredictable effects: in some cases acting as harmonic filters, but in others exacerbating distortion, particularly when interacting with internal LED drivers. Photometric assessments further highlight inconsistent luminous output and flicker performance, especially when magnetic ballasts remain in place. Lighting simulations demonstrate that although ballast-based retrofits may yield tolerable illuminance levels, they consistently exceed ASHRAE 90.1 power density limits and may lead to overillumination when luminaires are retrofitted one by one without considering the photometric quantities, which are unknown when LED tubes are placed in an existing luminaire. Techno-economic analysis confirms that full luminaire replacement with appropriately selected LED systems—combined with design optimization—achieves higher energy efficiency, shorter return on investment, and reliable compliance. Furthermore, the study includes an assessment of colorimetric characteristics and metrics relevant to human-centric lighting, such as the melanopic daylight efficacy ratio (MDER) and equivalent melanopic daylight illuminance, revealing significant variations between fluorescent and LED retrofit solutions. These findings emphasize the importance of evaluating not only energy and photometric performance but also biological lighting impacts when considering retrofit strategies. The findings emphasize that lighting retrofitting should not be treated as a simple lamp replacement but as a system-level intervention. Properly engineered LED replacements provide a more consistent, efficient, and sustainable solution, supporting the objectives of long-term reliability, regulatory alignment, and Sustainable Development Goals 3, 7, 9, 11, and 12.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3593623
Primary Topic
Impact of Light on Environment and Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

System-Level Analysis of LED Retrofit Solutions for T8 Fluorescent Tubes: Harmonic Emissions, Photometric Impacts, and Compliance Considerations

Eleni P. Nicolopoulou, Aikaterini D. Polykrati, Christos A. Christodoulou, Lambros Τ. Doulos et al.
IEEE Access
Impact of Light on Environment and Health
article

System-Level Analysis of LED Retrofit Solutions for T8 Fluorescent Tubes: Harmonic Emissions, Photometric Impacts, and Compliance Considerations

Eleni P. Nicolopoulou, Aikaterini D. Polykrati, Christos A. Christodoulou, Lambros Τ. Doulos, Evangelos-Nikolaos D. Madias, Ioannis F. Gonos, Themistoklis L. Athanasiadis
article en

Abstract

This study investigates the harmonic emissions, photometric performance, and technoeconomic implications of retrofitting T8 fluorescent tubes with LED alternatives under various ballast configurations. Experimental results reveal that while legacy fluorescent installations—whether magnetic or electronic—generally comply with EN IEC 61000-3-2 harmonic limits, most retrofit LED tube scenarios do not. The lack or ineffectiveness of power factor correction circuits in low-power LED tubes is identified as a key contributor to non-compliance. Moreover, the presence of magnetic ballasts introduces unpredictable effects: in some cases acting as harmonic filters, but in others exacerbating distortion, particularly when interacting with internal LED drivers. Photometric assessments further highlight inconsistent luminous output and flicker performance, especially when magnetic ballasts remain in place. Lighting simulations demonstrate that although ballast-based retrofits may yield tolerable illuminance levels, they consistently exceed ASHRAE 90.1 power density limits and may lead to overillumination when luminaires are retrofitted one by one without considering the photometric quantities, which are unknown when LED tubes are placed in an existing luminaire. Techno-economic analysis confirms that full luminaire replacement with appropriately selected LED systems—combined with design optimization—achieves higher energy efficiency, shorter return on investment, and reliable compliance. Furthermore, the study includes an assessment of colorimetric characteristics and metrics relevant to human-centric lighting, such as the melanopic daylight efficacy ratio (MDER) and equivalent melanopic daylight illuminance, revealing significant variations between fluorescent and LED retrofit solutions. These findings emphasize the importance of evaluating not only energy and photometric performance but also biological lighting impacts when considering retrofit strategies. The findings emphasize that lighting retrofitting should not be treated as a simple lamp replacement but as a system-level intervention. Properly engineered LED replacements provide a more consistent, efficient, and sustainable solution, supporting the objectives of long-term reliability, regulatory alignment, and Sustainable Development Goals 3, 7, 9, 11, and 12.

IEEE AccessVol. 13
National Technical University of Athens (GR), Hellenic Open University (GR)
Climate action
Openalex Percentile: Top 82%
Impact of Light on Environment and Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.