Impact of Transient EMG Signals on the Performance of a Gesture Recognition System

An Electromyography (EMG) based gesture recognition system takes myoelectric signals as input and uses these signals to predict hand movements. To predict the hand movements, three basic procedures are involved: signal processing, feature extraction, and classification. An EMG signal is combination of transient and static part observed during onset and hold state in a typical movement cycle. In this work, we investigated the impact of transient signals detected at the movement onset on the performance of a gesture-controlled system. We used transient, static, and complete signals to calculate the accuracy using LDA and kNN classifiers to evaluate the performance of the proposed study in different cases. The results indicate maximum accuracy with only static EMG signals and minimum accuracy while selecting only transient signals. The average accuracy for the LDA classifier with static signals is 83.29 %, and with transient signals, it is 61.53 %, signifying the impact of static signals in identifying movements.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/ariia63345.2024.11051783
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Transient EMG Signals on the Performance of a Gesture Recognition System

Ila Sharma, Nikhil Vivek Shrivas, Anil Sharma
Hand Gesture Recognition Systems
article

Impact of Transient EMG Signals on the Performance of a Gesture Recognition System

Ila Sharma, Nikhil Vivek Shrivas, Anil Sharma
article en

Abstract

An Electromyography (EMG) based gesture recognition system takes myoelectric signals as input and uses these signals to predict hand movements. To predict the hand movements, three basic procedures are involved: signal processing, feature extraction, and classification. An EMG signal is combination of transient and static part observed during onset and hold state in a typical movement cycle. In this work, we investigated the impact of transient signals detected at the movement onset on the performance of a gesture-controlled system. We used transient, static, and complete signals to calculate the accuracy using LDA and kNN classifiers to evaluate the performance of the proposed study in different cases. The results indicate maximum accuracy with only static EMG signals and minimum accuracy while selecting only transient signals. The average accuracy for the LDA classifier with static signals is 83.29 %, and with transient signals, it is 61.53 %, signifying the impact of static signals in identifying movements.

Manipal Hospital (IN), Malaviya National Institute of Technology Jaipur (IN)
Openalex Percentile: Top 69%
Hand Gesture Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.