Simple Ultrasound Imaging System Based on Dense and Sparse Selection and Activation of Array Transducer Elements

Ultrasound imaging is typically performed using an array transducer system. To obtain a direct 3D image instead of stacking 2D cross-sectional images, a 2D array is required, which requires a large amount of electronic circuitry. Therefore, simple single transducer systems are being investigated. However, these single-transducer systems require multiple echo receptions by rotating or translating the transducer to achieve sufficient image quality, making them difficult to apply to specific imaging targets. In this study, we propose a method that selectively connects multiple elements instead of using all elements of the array to receive independently, aiming to reduce the size of the receiving electronic circuitry. By selecting and connecting elements in dense and sparse patterns, we have developed a method that considers both resolution and signal-to-noise ratio. Through phantom experiments and human in vivo imaging experiments, it has been demonstrated that the proposed method achieves image quality equivalent to that of conventional array transducers.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3590062
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple Ultrasound Imaging System Based on Dense and Sparse Selection and Activation of Array Transducer Elements

Mohd. Syaryadhi, Norio Tagawa, Eiko Nakazawa
IEEE Access
Ultrasonics and Acoustic Wave Propagation
article

Simple Ultrasound Imaging System Based on Dense and Sparse Selection and Activation of Array Transducer Elements

Mohd. Syaryadhi, Norio Tagawa, Eiko Nakazawa
article en

Abstract

Ultrasound imaging is typically performed using an array transducer system. To obtain a direct 3D image instead of stacking 2D cross-sectional images, a 2D array is required, which requires a large amount of electronic circuitry. Therefore, simple single transducer systems are being investigated. However, these single-transducer systems require multiple echo receptions by rotating or translating the transducer to achieve sufficient image quality, making them difficult to apply to specific imaging targets. In this study, we propose a method that selectively connects multiple elements instead of using all elements of the array to receive independently, aiming to reduce the size of the receiving electronic circuitry. By selecting and connecting elements in dense and sparse patterns, we have developed a method that considers both resolution and signal-to-noise ratio. Through phantom experiments and human in vivo imaging experiments, it has been demonstrated that the proposed method achieves image quality equivalent to that of conventional array transducers.

IEEE AccessVol. 13
Tokyo Metropolitan University (JP)
Tokyo Metropolitan University
Openalex Percentile: Top 79%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.