The CMS barrel timing layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of 2×1014 1 MeV neq/cm2). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30–60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 μm cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-07-19
DOI
https://doi.org/10.1016/j.nima.2025.170823
Citations
2
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The CMS barrel timing layer: test beam confirmation of module timing performance

F. Lombardi, G. Sorrentino, D. Baranyai, Aurora Perego et al.
2 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
3.74
article

The CMS barrel timing layer: test beam confirmation of module timing performance

F. Lombardi, G. Sorrentino, D. Baranyai, Aurora Perego, F. De Guio, José María, D. Mazzaro, Giorgio Pizzati, Enrique Fernández, Y. Maravin, C. Tully, K. Dreimanis, Alessio Boletti, Zhisheng Wu, R. Carlin, Ojars Martins Eberlins, A. Krishna, M. T. Lucchini, F. Errico, Antra Gaile, S. N. White, R. Silva, Alexander Ledovskoy, Z. Hu, Robert Bianco, Andrea Claudio Maria Bulla, C. Neu, K. De Leo, F. Riggi, N. Bez, Denes Szabó, Dimitrios Sidiropoulos Kontos, R. Taylor, Normunds Ralfs Strautnieks, Lautaro Narváez, Stefania Ronchi, S. Bhattacharya, A Benato, Ruben Gargiulo, C. Quaranta, F. M. Addesa, P. Barria, M. Titov, T. Tabarelli de Fatis, Prabhat Solanki, R. Isocrate, D. Osite, Guntis Pikurs, X. Sun, Raffaele Delli Gatti, Z. Li, Gina M. Trabucco, Braden Kronheim, M. Turcato, Zuoqiang Hao, B. Ujvári, Saulius Nargelas, Simona Palluotto, Linfeng Li, L. Zhang, Giovanni Organtini, M. Paganoni, W. Funk, M. Casarsa, P. Meridiani, Francesco Pandolfi, F. Cossutti, R. Gerosa, D. Del Re, Conrado Munoz Diaz, Chiara Basile, Richard Wynne, L. Soffi, N. Redaelli, Paul Devouge, M. Spiropulu, M.Ö. Sahin, J. Babbar, G. Zilizi, G. Reales Gutiérrez, M. Benettoni, P. Simmerling, B. Gyöngyösi, M. Besancon, Martina Malberti, A. Ghezzi, A. Benaglia, M. Gallinaro, D. Blend, F. Veronese, V. Lohezic, O.K. Köseyan, Y. Musienko, M. Tosi, J. Varela, P. Debbins, A. Heering, R. Paramatti, R. Rossin, A. Tsirou, A. Karneyeu, C. Palmer, M.S. Kim, A. Albert, M. Wayne, G. Tamulaitis, C. Royon, Y. Mao, Adolf Bornheim, B. Cox, F. Santanastasio, B. Marzocchi, John Dervan, M. Zhang, V. Vladimirov, T. Anderson, R. Bugalho, T. Orimoto, I. Schmidt, Johan Wilfried Wulff, P. Dini, G. Da Molin, Jing Wang, S. Rahatlou, Petra Akrap, R. Menon Raghunandanan, T Pauletto, Robert Plese, Thomas Sievert
article en
2 citations

Abstract

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of 2×1014 1 MeV neq/cm2). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30–60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 μm cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1081
Université Paris-Saclay (FR)
CERN, European Commission, National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, HORIZON EUROPE Framework Programme, Fundação para a Ciência e a Tecnologia
Affordable and clean energy
Openalex Percentile: Top 7%
Particle Detector Development and Performance
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.