Study on the Shear Performance of MMOM Stay-in-Place Formwork Beams Reinforced with Perforated Steel Pipe Skeleton

The simulation analysis of a novel stay-in-place formwork (SIPF) beam reinforced with perforated steel pipe skeleton was conducted. The SIPF beam consists of a modified magnesium oxysulfide mortar (MMOM) formwork, a square steel pipe skeleton with holes dug on the sides and top, and cast-in-place concrete. The finite element (FE) analysis model of the SIPF beam was established by using the ABAQUS CAE 2021 software, and simulation analysis was conducted with the shear span ratio (SSR), the distance between the remaining steel strips, and the strength of concrete as the variation parameters. The results show that the stiffness and shear capacity of the SIPF beam decrease with the increase in SSR and increase with the decrease in strip spacing. Under the same conditions, when the concrete strength grade is increased from C30 to C50, the shear bearing capacity of the SIPF beam increases by 11.8% to 16.2%. When the spacing of the steel strips is reduced from 200 mm to 150 mm, the shear bearing capacity can be increased by 12.7% to 31.5%. When the SSR increases from 1.5 to 3.0, the shear bearing capacity decreases by 26.9% to 37.3%. Moreover, with the increase in the SSR, the influence of the steel strip spacing on the shear bearing capacity of the SIPF beam improves, while the influence of the concrete strength on the shear bearing capacity decreases. Taking parameters such as SSR, steel strip spacing, and concrete strength as variables, the influence of steel pipe constraining the core concrete on the shear bearing capacity was considered. The calculation formula for the shear bearing capacity of the SIPF beam with perforated steel pipe skeleton was established. The calculation results fit well with the laboratory test and simulation test results and can be used for the design and calculation of engineering structures.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-07-26
DOI
https://doi.org/10.3390/buildings15152638
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Shear Performance of MMOM Stay-in-Place Formwork Beams Reinforced with Perforated Steel Pipe Skeleton

Changhua Shang, Lingling Li, Xiaodong Wang
Buildings
Structural Load-Bearing Analysis
article

Study on the Shear Performance of MMOM Stay-in-Place Formwork Beams Reinforced with Perforated Steel Pipe Skeleton

Changhua Shang, Lingling Li, Xiaodong Wang
article en

Abstract

The simulation analysis of a novel stay-in-place formwork (SIPF) beam reinforced with perforated steel pipe skeleton was conducted. The SIPF beam consists of a modified magnesium oxysulfide mortar (MMOM) formwork, a square steel pipe skeleton with holes dug on the sides and top, and cast-in-place concrete. The finite element (FE) analysis model of the SIPF beam was established by using the ABAQUS CAE 2021 software, and simulation analysis was conducted with the shear span ratio (SSR), the distance between the remaining steel strips, and the strength of concrete as the variation parameters. The results show that the stiffness and shear capacity of the SIPF beam decrease with the increase in SSR and increase with the decrease in strip spacing. Under the same conditions, when the concrete strength grade is increased from C30 to C50, the shear bearing capacity of the SIPF beam increases by 11.8% to 16.2%. When the spacing of the steel strips is reduced from 200 mm to 150 mm, the shear bearing capacity can be increased by 12.7% to 31.5%. When the SSR increases from 1.5 to 3.0, the shear bearing capacity decreases by 26.9% to 37.3%. Moreover, with the increase in the SSR, the influence of the steel strip spacing on the shear bearing capacity of the SIPF beam improves, while the influence of the concrete strength on the shear bearing capacity decreases. Taking parameters such as SSR, steel strip spacing, and concrete strength as variables, the influence of steel pipe constraining the core concrete on the shear bearing capacity was considered. The calculation formula for the shear bearing capacity of the SIPF beam with perforated steel pipe skeleton was established. The calculation results fit well with the laboratory test and simulation test results and can be used for the design and calculation of engineering structures.

BuildingsVol. 15(15)
Harbin University of Science and Technology (CN), Jilin University (CN), Jilin Jianzhu University (CN), Health Commission of Jilin Province (CN), Guizhou Water Conservancy and Hydropower Survey and Design Institute (CN), Ningxia Water Conservancy (CN)
People's Government of Jilin Province, Education Department of Jilin Province
Openalex Percentile: Top 81%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.