Simple and robust analysis of cefuroxime in human plasma and bone tissues by LC-MS/MS

In end-stage osteoarthritis, total joint arthroplasty (TJA) represents the definitive therapeutic intervention. Cefuroxime, a second-generation cephalosporin, exhibits a broad spectrum of activity against both Gram-negative and Gram-positive microorganisms, making it a cornerstone of surgical antimicrobial prophylaxis (SAP) to mitigate prosthetic joint infection (PJI) risk. However, the escalating demand for revision arthroplasties has paralleled rising implant-associated infections, necessitating target-site pharmacokinetic optimization to ensure effective antibiotic exposure at the bone-implant interface. Therefore, we developed a validated liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for simultaneous quantification of cefuroxime in human plasma and bone tissues. The separation was completed in 7.5 min on a BEH C<sub>18</sub> column (2.1 × 50 mm, 3.5 μm), and the gradient elution was performed in a mobile phase consisting of 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL min<sup>-1</sup>. The correlation coefficients of calibration curves were all greater than 0.99. The detection accuracy of plasma ranged from 93.11% to 98.60% (89.15-106.2% for bone). The intra- and inter-assay precision for both plasma and bone measurements were within 15% (20% at the lower limit of quantitation, LLOQ). The matrix effects were 2.34% to 2.91% in plasma and 3.13-5.17% in bone, while extraction recoveries ranged from 99.8% to 102.0% for plasma and 105.0-107.0% for bone. Upon stability assessment under varying storage conditions, all samples exhibited a difference of less than 15.0%. The method was successfully applied to the determination of cefuroxime in plasma and bone tissues of actual patients.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay01085c
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simple and robust analysis of cefuroxime in human plasma and bone tissues by LC-MS/MS

Z. Wang, Hui Ma, Yuanyuan Zhang, Yanan Wang et al.
Analytical Methods
Antibiotics Pharmacokinetics and Efficacy
article

Simple and robust analysis of cefuroxime in human plasma and bone tissues by LC-MS/MS

Z. Wang, Hui Ma, Yuanyuan Zhang, Yanan Wang, Xin Xiong, Sihan Wang, Qing Ling, Libo Zhao
article en

Abstract

In end-stage osteoarthritis, total joint arthroplasty (TJA) represents the definitive therapeutic intervention. Cefuroxime, a second-generation cephalosporin, exhibits a broad spectrum of activity against both Gram-negative and Gram-positive microorganisms, making it a cornerstone of surgical antimicrobial prophylaxis (SAP) to mitigate prosthetic joint infection (PJI) risk. However, the escalating demand for revision arthroplasties has paralleled rising implant-associated infections, necessitating target-site pharmacokinetic optimization to ensure effective antibiotic exposure at the bone-implant interface. Therefore, we developed a validated liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for simultaneous quantification of cefuroxime in human plasma and bone tissues. The separation was completed in 7.5 min on a BEH C<sub>18</sub> column (2.1 × 50 mm, 3.5 μm), and the gradient elution was performed in a mobile phase consisting of 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL min<sup>-1</sup>. The correlation coefficients of calibration curves were all greater than 0.99. The detection accuracy of plasma ranged from 93.11% to 98.60% (89.15-106.2% for bone). The intra- and inter-assay precision for both plasma and bone measurements were within 15% (20% at the lower limit of quantitation, LLOQ). The matrix effects were 2.34% to 2.91% in plasma and 3.13-5.17% in bone, while extraction recoveries ranged from 99.8% to 102.0% for plasma and 105.0-107.0% for bone. Upon stability assessment under varying storage conditions, all samples exhibited a difference of less than 15.0%. The method was successfully applied to the determination of cefuroxime in plasma and bone tissues of actual patients.

Analytical MethodsVol. 17(34)
Peking University (CN), Peking University Third Hospital (CN)
Openalex Percentile: Top 79%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.