Safety and Anatomical Accuracy of Dry Needling of the Quadratus Femoris Muscle: A Cadaveric Study

<b>Introduction:</b> Deep dry needling (DDN) is commonly applied in physiotherapy to treat musculoskeletal pain. The quadratus femoris (QF) muscle, located in the ischiofemoral space (IFS), represents a clinically relevant yet anatomically complex target. However, limited evidence exists on the safety, accuracy, and reliability of non-ultrasound-guided DDN in this region. <b>Aims:</b> To assess the safety and accuracy of a standardized, non-ultrasound-guided DDN approach to the QF muscle, and to evaluate the intra- and inter-rater reliability of key procedural outcomes. Additionally, to determine the agreement between ultrasound imaging and anatomical dissection as validation methods for needle placement. <b>Methods:</b> An experimental cross-sectional study was conducted on five fresh cadavers (n = 24 approaches) by two physiotherapists with different DN experience. A standardized dry needling protocol was executed without ultrasound guidance, and anatomical and procedural variables were documented. Reliability (intra/inter-rater) was assessed for needle size, sciatic nerve (SN) puncture, IFS targeting, and overall success. In a subset, needle placement was validated through ultrasound and subsequent dissection. <b>Results:</b> The IFS was reached in 70.8% of procedures, and the SN was punctured in 16.7%. Inter-rater reliability for needle size was poor (κ = 0.04). Agreement between ultrasound and dissection was excellent for the ischiofemoral location and success (100%) and moderate for non SN puncture (90%; κ = 0.62). <b>Conclusions:</b> The standardized protocol demonstrated moderate accuracy and revealed a relevant clinical risk when targeting the quadratus femoris muscle. While inter-rater reliability was limited, agreement between ultrasound and dissection methods was high, supporting their complementary use for validating needle placement in anatomically complex procedures.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-07-26
DOI
https://doi.org/10.3390/healthcare13151828
Citations
1
Primary Topic
Myofascial pain diagnosis and treatment
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and Anatomical Accuracy of Dry Needling of the Quadratus Femoris Muscle: A Cadaveric Study

Ángel González‐de‐la‐Flor, N. Alayón Hernández, Jaime Almazán-Polo, D. Monreal-Redondo et al.
1 citations
Healthcare
Myofascial pain diagnosis and treatment
1.15
article

Safety and Anatomical Accuracy of Dry Needling of the Quadratus Femoris Muscle: A Cadaveric Study

Ángel González‐de‐la‐Flor, N. Alayón Hernández, Jaime Almazán-Polo, D. Monreal-Redondo, Fabien Guérineau, Charles Cotteret, Marta Sánchez-Montoya
article en
1 citations

Abstract

<b>Introduction:</b> Deep dry needling (DDN) is commonly applied in physiotherapy to treat musculoskeletal pain. The quadratus femoris (QF) muscle, located in the ischiofemoral space (IFS), represents a clinically relevant yet anatomically complex target. However, limited evidence exists on the safety, accuracy, and reliability of non-ultrasound-guided DDN in this region. <b>Aims:</b> To assess the safety and accuracy of a standardized, non-ultrasound-guided DDN approach to the QF muscle, and to evaluate the intra- and inter-rater reliability of key procedural outcomes. Additionally, to determine the agreement between ultrasound imaging and anatomical dissection as validation methods for needle placement. <b>Methods:</b> An experimental cross-sectional study was conducted on five fresh cadavers (n = 24 approaches) by two physiotherapists with different DN experience. A standardized dry needling protocol was executed without ultrasound guidance, and anatomical and procedural variables were documented. Reliability (intra/inter-rater) was assessed for needle size, sciatic nerve (SN) puncture, IFS targeting, and overall success. In a subset, needle placement was validated through ultrasound and subsequent dissection. <b>Results:</b> The IFS was reached in 70.8% of procedures, and the SN was punctured in 16.7%. Inter-rater reliability for needle size was poor (κ = 0.04). Agreement between ultrasound and dissection was excellent for the ischiofemoral location and success (100%) and moderate for non SN puncture (90%; κ = 0.62). <b>Conclusions:</b> The standardized protocol demonstrated moderate accuracy and revealed a relevant clinical risk when targeting the quadratus femoris muscle. While inter-rater reliability was limited, agreement between ultrasound and dissection methods was high, supporting their complementary use for validating needle placement in anatomically complex procedures.

HealthcareVol. 13(15)
Universidad Complutense de Madrid (ES), Universidad Europea de Madrid (ES)
Openalex Percentile: Top 22%
Myofascial pain diagnosis and treatment
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.