A Novel CTC-Binding Probe: Enzymatic vs. Shear Stress-Based Detachment Approaches

<b>Background/Objectives</b>: Liquid biopsy is a minimally invasive alternative to tissue biopsy and is used to obtain information about a disease from a blood sample or other body fluids. In the context of cancer, circulating tumor cells (CTC) can be used as biomarkers to determine the nature of the tumor, its stage of progression, and the efficiency of the administered therapy through monitoring. However, the low concentration of CTCs in blood (1-10 cells/mL) is a challenge for their isolation. Therefore, a minimally invasive medical device (BMProbe™) was developed that isolates CTCs via antigen-antibody binding directly from the bloodstream. Current investigations focus on the process of detaching bound cells from the BMProbe™ surface for cell cultivation and subsequent drug testing to enable personalized therapy planning. <b>Methods</b>: This article presents two approaches for detaching LNCaP cells from anti-EpCAM coated BMProbes™: enzymatic detachment using TrypLE™ and detachment through enzymatic pretreatment with supplementary flow-induced shear stress. The additional shear stress is intended to increase the detachment efficiency. To determine the flow rate required to gently detach the cells, a computational fluid dynamics (CFD) simulation was carried out. <b>Results</b>: The experimental test results demonstrate that 91% of the bound cells can be detached enzymatically within 10 min. Based on the simulation, a maximum flow rate of 47.76 mL/min was defined in the flow detachment system, causing an average shear stress of 8.4 Pa at the probe edges. The additional flow treatment did not increase the CTC detachment efficiency. <b>Conclusions</b>: It is feasible that the detachment efficiency can be further increased by a longer enzymatic incubation time or higher shear stress. The influence on the integrity and viability of cells must, however, be considered.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-07-26
DOI
https://doi.org/10.3390/diagnostics15151876
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel CTC-Binding Probe: Enzymatic vs. Shear Stress-Based Detachment Approaches

Ulrich Kertzscher, Felix Hehnen, Paul Geus, Hans Wolff et al.
Diagnostics
Microfluidic and Bio-sensing Technologies
article

A Novel CTC-Binding Probe: Enzymatic vs. Shear Stress-Based Detachment Approaches

Ulrich Kertzscher, Felix Hehnen, Paul Geus, Hans Wolff, Michael Lommel, Sara Campos, Sophia Krakowski, Gabi Bondzio
article en

Abstract

<b>Background/Objectives</b>: Liquid biopsy is a minimally invasive alternative to tissue biopsy and is used to obtain information about a disease from a blood sample or other body fluids. In the context of cancer, circulating tumor cells (CTC) can be used as biomarkers to determine the nature of the tumor, its stage of progression, and the efficiency of the administered therapy through monitoring. However, the low concentration of CTCs in blood (1-10 cells/mL) is a challenge for their isolation. Therefore, a minimally invasive medical device (BMProbe™) was developed that isolates CTCs via antigen-antibody binding directly from the bloodstream. Current investigations focus on the process of detaching bound cells from the BMProbe™ surface for cell cultivation and subsequent drug testing to enable personalized therapy planning. <b>Methods</b>: This article presents two approaches for detaching LNCaP cells from anti-EpCAM coated BMProbes™: enzymatic detachment using TrypLE™ and detachment through enzymatic pretreatment with supplementary flow-induced shear stress. The additional shear stress is intended to increase the detachment efficiency. To determine the flow rate required to gently detach the cells, a computational fluid dynamics (CFD) simulation was carried out. <b>Results</b>: The experimental test results demonstrate that 91% of the bound cells can be detached enzymatically within 10 min. Based on the simulation, a maximum flow rate of 47.76 mL/min was defined in the flow detachment system, causing an average shear stress of 8.4 Pa at the probe edges. The additional flow treatment did not increase the CTC detachment efficiency. <b>Conclusions</b>: It is feasible that the detachment efficiency can be further increased by a longer enzymatic incubation time or higher shear stress. The influence on the integrity and viability of cells must, however, be considered.

DiagnosticsVol. 15(15)
Humboldt-Universität zu Berlin (DE), Micro Resist Technology (Germany) (DE), Deutsches Herzzentrum der Charité (DE), Freie Universität Berlin (DE), Charité - Universitätsmedizin Berlin (DE)
European Regional Development Fund
Good health and well-being
Openalex Percentile: Top 83%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.