Studi Numerik Pengaruh Perubahan Sudut Masuk Dan Sudut Keluar Blade Terhadap Performa Axial Fan 445MM

The use of axial fans for air handling units on ships is still widely used because axial fans produce higher flowrates than centrifugal fans when pressure requirements are relatively low. Many companies produce axial fans but they do not care about the resulting performance. As a result, the flowrate requirements for air handling units are not met. Now many domestic companies are developing axial fans to maximize the performance of axial fans.To maximize the performance of the axial fan, several modifications are made. Many modifications are made such as modifying the blade inlet and outlet angles, the number of blades, blade profiles. In this study, modifications will be made to the inlet angle and outlet angle of the airfoil. The airfoil inlet angle will be increased by 1° and reduced by 1° while the airfoil outlet angle will be increased by 1° and reduced by 1°. In this study, 3D modeling was carried out using CFD (Computational Fluid Dynamics) method.After modifying the inlet and outlet angles on the axial fan, the most optimal variation is to increase by 1° the outlet angle of the trailing edges because it has a relatively large flow coefficient and power coefficient value.

Publication Details

Published
2025-07-13
DOI
https://doi.org/10.33863/cmea.v7i1.3155
Primary Topic
Mechanical Engineering and Vibrations Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studi Numerik Pengaruh Perubahan Sudut Masuk Dan Sudut Keluar Blade Terhadap Performa Axial Fan 445MM

Mechanical Engineering and Vibrations Research
article

Studi Numerik Pengaruh Perubahan Sudut Masuk Dan Sudut Keluar Blade Terhadap Performa Axial Fan 445MM

article en

Abstract

The use of axial fans for air handling units on ships is still widely used because axial fans produce higher flowrates than centrifugal fans when pressure requirements are relatively low. Many companies produce axial fans but they do not care about the resulting performance. As a result, the flowrate requirements for air handling units are not met. Now many domestic companies are developing axial fans to maximize the performance of axial fans.To maximize the performance of the axial fan, several modifications are made. Many modifications are made such as modifying the blade inlet and outlet angles, the number of blades, blade profiles. In this study, modifications will be made to the inlet angle and outlet angle of the airfoil. The airfoil inlet angle will be increased by 1° and reduced by 1° while the airfoil outlet angle will be increased by 1° and reduced by 1°. In this study, 3D modeling was carried out using CFD (Computational Fluid Dynamics) method.After modifying the inlet and outlet angles on the axial fan, the most optimal variation is to increase by 1° the outlet angle of the trailing edges because it has a relatively large flow coefficient and power coefficient value.

Openalex Percentile: Top 82%
Mechanical Engineering and Vibrations Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Studi Numerik Pengaruh Perubahan Sudut Masuk Dan Sudut Keluar Blade Terhadap Performa Axial Fan 445MM · (2025) | TGRS Research Map | TGRS