Studi Numerik Pengaruh Sudut Stagger Silinder Di Depan Returning Blade Turbin Angin Savonius Dengan Sudu Overlap Berprofil Myring n=1

In the previous experimental studies, additional overlap using Myring equation n=1 and variations in the cylinder stagger angle in front of returning blade of Savonius wind turbine could not display flow visualizations such as velocity contours, streamline velocity, and pressure contours. Based on these conditions, this numerical study was conducted using Computational Fluid Dynamics method. The simulation is performed to validate the experimental results, determine the coefficient of torque (Ct), coefficient of power (Cp), and visualize the turbine flow. The diameter and height of the turbine used are 400 mm with an overlap ratio of 0.3. The stagger angle variations of cylinder are 45°, 50°, 55° and 60° with 6 m/s wind speed. The best turbine performance occurs at a stagger angle of 60°, with an increase up to 19.39% of CP value compared to the Savonius wind turbine with Myring overlap n=1 without a stagger cylinder, with a Cp value of 0.394 at Tip Speed Ratio of 1.

Publication Details

Published
2025-07-13
DOI
https://doi.org/10.33863/cmea.v7i1.3170
Primary Topic
Magnetic Bearings and Levitation Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studi Numerik Pengaruh Sudut Stagger Silinder Di Depan Returning Blade Turbin Angin Savonius Dengan Sudu Overlap Berprofil Myring n=1

Magnetic Bearings and Levitation Dynamics
article

Studi Numerik Pengaruh Sudut Stagger Silinder Di Depan Returning Blade Turbin Angin Savonius Dengan Sudu Overlap Berprofil Myring n=1

article en

Abstract

In the previous experimental studies, additional overlap using Myring equation n=1 and variations in the cylinder stagger angle in front of returning blade of Savonius wind turbine could not display flow visualizations such as velocity contours, streamline velocity, and pressure contours. Based on these conditions, this numerical study was conducted using Computational Fluid Dynamics method. The simulation is performed to validate the experimental results, determine the coefficient of torque (Ct), coefficient of power (Cp), and visualize the turbine flow. The diameter and height of the turbine used are 400 mm with an overlap ratio of 0.3. The stagger angle variations of cylinder are 45°, 50°, 55° and 60° with 6 m/s wind speed. The best turbine performance occurs at a stagger angle of 60°, with an increase up to 19.39% of CP value compared to the Savonius wind turbine with Myring overlap n=1 without a stagger cylinder, with a Cp value of 0.394 at Tip Speed Ratio of 1.

Openalex Percentile: Top 79%
Magnetic Bearings and Levitation Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.