Nanostructured gold platforms for attogram-precision cardiolipin quantification

An ultra-sensitive electrochemical immunosensor is presented for the precise quantification of cardiolipin, a key biomarker of mitochondrial dysfunction and cardiovascular pathologies. This innovative platform utilizes two distinct gold nanostructures, nanorods and nanodendrites, within the sensing electrode to achieve exceptional sensitivity and selectivity. These nanostructures were synthesized through a sequential process involving physical vapor deposition of an ultrathin gold film, thermal annealing to nucleate gold seeds, and precision electrochemical deposition, enabling controlled growth on fluorine-doped tin oxide (FTO) substrates. This template-free strategy, optimized through systematic parameter refinement, ensures high reproducibility and electrochemical efficiency. Unlike conventional colloidal synthesis methods that rely on seed-mediated growth and extensive surfactant usage, our template-free electrochemical approach offers a simpler, more reproducible, and surfactant-reduced route for fabricating well-controlled gold nanostructures suitable for biocompatible sensing platforms. Morphological, structural, and surface characterization of the nanostructures was performed using field emission scanning electron microscopy, X-ray diffraction, and contact angle measurements, confirming well-defined growth and controlled surface wettability. Electrochemical analyses, including cyclic voltammetry and electrochemical impedance spectroscopy, further revealed enhanced electron transfer and reduced interfacial resistance, verifying their suitability for sensitive biosensing applications. Functionalization with anti-cardiolipin antibodies ensures high specificity. Electrochemical measurements reveal a dynamic linear range (1 ag mL<sup>-1</sup> to 0.1 pg mL<sup>-1</sup>) and detection limits of 0.19 ag mL<sup>-1</sup> (nanorods) and 0.51 ag mL<sup>-1</sup> (nanodendrites). Nanorods demonstrate superior charge transfer, lower impedance, and greater accessibility, positioning this scalable platform as a paradigm shift for lipidomic profiling and advanced diagnostics in precision medicine.

Authors

Institutions

Publication Details

Journal
Journal of Materials Chemistry B
Published
2025-01-01
DOI
https://doi.org/10.1039/d5tb00798d
Citations
1
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanostructured gold platforms for attogram-precision cardiolipin quantification

Jahangir Mohammadzadeh, Ahmad Moshaii, Reza H. Sajedi, Mehrsa Khalilipour et al.
1 citations
Journal of Materials Chemistry B
Electrochemical Analysis and Applications
0.52
article

Nanostructured gold platforms for attogram-precision cardiolipin quantification

Jahangir Mohammadzadeh, Ahmad Moshaii, Reza H. Sajedi, Mehrsa Khalilipour, Sadaf Yarjoo, Hossien Siampour
article en
1 citations

Abstract

An ultra-sensitive electrochemical immunosensor is presented for the precise quantification of cardiolipin, a key biomarker of mitochondrial dysfunction and cardiovascular pathologies. This innovative platform utilizes two distinct gold nanostructures, nanorods and nanodendrites, within the sensing electrode to achieve exceptional sensitivity and selectivity. These nanostructures were synthesized through a sequential process involving physical vapor deposition of an ultrathin gold film, thermal annealing to nucleate gold seeds, and precision electrochemical deposition, enabling controlled growth on fluorine-doped tin oxide (FTO) substrates. This template-free strategy, optimized through systematic parameter refinement, ensures high reproducibility and electrochemical efficiency. Unlike conventional colloidal synthesis methods that rely on seed-mediated growth and extensive surfactant usage, our template-free electrochemical approach offers a simpler, more reproducible, and surfactant-reduced route for fabricating well-controlled gold nanostructures suitable for biocompatible sensing platforms. Morphological, structural, and surface characterization of the nanostructures was performed using field emission scanning electron microscopy, X-ray diffraction, and contact angle measurements, confirming well-defined growth and controlled surface wettability. Electrochemical analyses, including cyclic voltammetry and electrochemical impedance spectroscopy, further revealed enhanced electron transfer and reduced interfacial resistance, verifying their suitability for sensitive biosensing applications. Functionalization with anti-cardiolipin antibodies ensures high specificity. Electrochemical measurements reveal a dynamic linear range (1 ag mL<sup>-1</sup> to 0.1 pg mL<sup>-1</sup>) and detection limits of 0.19 ag mL<sup>-1</sup> (nanorods) and 0.51 ag mL<sup>-1</sup> (nanodendrites). Nanorods demonstrate superior charge transfer, lower impedance, and greater accessibility, positioning this scalable platform as a paradigm shift for lipidomic profiling and advanced diagnostics in precision medicine.

Journal of Materials Chemistry BVol. 13(36)
Tarbiat Modares University (IR)
Tarbiat Modares University
Openalex Percentile: Top 39%
Electrochemical Analysis and Applications
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.