The role of ultrasound monitor positioning in internal jugular vein catheterization: A randomized clinical trial on ergonomic optimization
Ergonomic ultrasound monitor positioning reduces complication rates during CICCs placement without affecting procedure duration or success rates. These findings support integrating ergonomic principles into clinical training. However, further studies are needed to confirm these benefits in real-world settings and across different procedures.
Authors
- Alessandro De Cassai (ORCID: https://orcid.org/0000-0002-9773-1832)
- Annalisa Boscolo (ORCID: https://orcid.org/0000-0003-3409-4159)
- Giulia Mormando (ORCID: https://orcid.org/0000-0001-9516-9885)
- Paolo Navalesi (ORCID: https://orcid.org/0000-0002-3733-3453)
- Gianluca Borio (ORCID: https://orcid.org/0000-0002-3034-6163)
- Francesco Zarantonello (ORCID: https://orcid.org/0000-0002-5217-9669)
- Alessandra Maggiolo
- Chiara Bertoncello (ORCID: https://orcid.org/0000-0003-4040-8601)
- Anna Vittadello (ORCID: https://orcid.org/0009-0006-4356-2072)
- Carmine Ruopolo
Institutions
- University of Padua (IT)
- Azienda Ospedaliero Universitaria Ospedali Riuniti (IT)
Publication Details
- Journal
- The Journal of Vascular Access
- Published
- 2025-07-26
- DOI
- https://doi.org/10.1177/11297298251359034
- Primary Topic
- Central Venous Catheters and Hemodialysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00