Effect of blade trailing edge treatment on the hemolysis and hydraulic performance of left ventricular assist device

Left ventricular assist devices (LVADs) provide an effective artificial support treatment for patients with advanced-stage heart failure. To enhance the LVAD performance and optimize its internal flow field, different blade trailing edge treatment techniques are employed. This study mainly investigates the effects of two methods: bladelet and blade trimming. The effectiveness of these two techniques in LVADs has not been thoroughly evaluated in previous research. The flow field distribution and hydraulic performance of different impellers are obtained by computational fluid dynamics (CFD) simulations. The results reveal that bladelets can significantly weaken the hydraulic performance of LVADs. However, the appropriate bladelet parameters can reduce the hemolysis value and improve hemocompatibility. Similarly, suitable blade trimming parameters can optimize the hemocompatibility of LVADs. Nevertheless, excessive blade trimming can increase hemolysis. Lastly, blade trimming has minimal impact on the hydraulic performance of LVADs.

Authors

Institutions

Publication Details

Journal
iScience
Published
2025-07-26
DOI
https://doi.org/10.1016/j.isci.2025.113222
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of blade trailing edge treatment on the hemolysis and hydraulic performance of left ventricular assist device

Yumei Li, Liangwan Chen, Zhihuang Qiu, Yuejiao Liu et al.
iScience
Mechanical Circulatory Support Devices
article

Effect of blade trailing edge treatment on the hemolysis and hydraulic performance of left ventricular assist device

Yumei Li, Liangwan Chen, Zhihuang Qiu, Yuejiao Liu, Chuang Cao
article en

Abstract

Left ventricular assist devices (LVADs) provide an effective artificial support treatment for patients with advanced-stage heart failure. To enhance the LVAD performance and optimize its internal flow field, different blade trailing edge treatment techniques are employed. This study mainly investigates the effects of two methods: bladelet and blade trimming. The effectiveness of these two techniques in LVADs has not been thoroughly evaluated in previous research. The flow field distribution and hydraulic performance of different impellers are obtained by computational fluid dynamics (CFD) simulations. The results reveal that bladelets can significantly weaken the hydraulic performance of LVADs. However, the appropriate bladelet parameters can reduce the hemolysis value and improve hemocompatibility. Similarly, suitable blade trimming parameters can optimize the hemocompatibility of LVADs. Nevertheless, excessive blade trimming can increase hemolysis. Lastly, blade trimming has minimal impact on the hydraulic performance of LVADs.

iScienceVol. 28(9)
Fujian Medical University (CN), Union Hospital (CN), Fuzhou University (CN)
Good health and well-being
Openalex Percentile: Top 83%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of blade trailing edge treatment on the hemolysis and hydraulic performance of left ventricular assist device — Yumei Li, Liangwan Chen, et al. · iScience (2025) | TGRS Research Map | TGRS