A Data-Driven Framework for Optimizing Propranolol Dosage Using Support Vector Regression and Reinforcement Learning

The accurate prediction and adjustment of drug dosages requires precision to maximize therapeutic benefits while minimizing harm. This research attempts to model a hybrid machine learning framework combining Support Vector Regression (SVR) and Reinforcement Learning (RL) for individualized Propranolol dosage optimization using patient-specific clinical, enzymatic, and lifestyle data. A retrospective dataset comprising patient file, lifestyle indicators, and enzyme profile was used to train an SVR model for initial dosage prediction. Reinforcement Learning was subsequently applied to refine predictions through simulated feedback loops. Model performance was assessed using Mean Squared Error (MSE), R-squared (R²), and F1-score. Statistical comparisons between SVR predictions, RL-refined dosages, and physician-prescribed doses were performed using paired t-tests and one-way ANOVA. The SVR model achieved high predictive accuracy (MSE = 0.3554; R² = 0.9835), indicating its suitability for dosage estimation. The RL-refined model demonstrated a slight decrease in accuracy (MSE = 0.9928; R² = 0.9539). Statistical tests showed no significant improvement with RL (paired t-test: t = -1.1132, p = 0.2672; ANOVA: F = 0.0165, p = 0.9836). Mean predicted dosages across SVR, RL, and physician prescriptions were closely aligned (24.85 mg, 24.83 mg, and 24.93 mg, respectively). This study demonstrates that even standalone SVR may yield Propranolol dosage estimates with high accuracy, highlighting its prospective usefulness in clinical settings as a direct yet reliable tool for use in customized healthcare. While RL does offer some level of flexibility, the statistical value of improvements made was negligible, making RL beneficial but not necessarily critical. The proposed model shows that AI systems can aid in formulating evidence-based clinical judgments for dosing medications.

Authors

Institutions

Publication Details

Journal
Journal of Information Systems and Informatics
Published
2025-06-24
DOI
https://doi.org/10.51519/journalisi.v7i2.1075
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Data-Driven Framework for Optimizing Propranolol Dosage Using Support Vector Regression and Reinforcement Learning

Frank Edughom Ekpar, Sunday Awofisayo, Simeon Ozuomba, Felix Anayo Njoku
Journal of Information Systems and Informatics
Hemodynamic Monitoring and Therapy
article

A Data-Driven Framework for Optimizing Propranolol Dosage Using Support Vector Regression and Reinforcement Learning

Frank Edughom Ekpar, Sunday Awofisayo, Simeon Ozuomba, Felix Anayo Njoku
article en

Abstract

The accurate prediction and adjustment of drug dosages requires precision to maximize therapeutic benefits while minimizing harm. This research attempts to model a hybrid machine learning framework combining Support Vector Regression (SVR) and Reinforcement Learning (RL) for individualized Propranolol dosage optimization using patient-specific clinical, enzymatic, and lifestyle data. A retrospective dataset comprising patient file, lifestyle indicators, and enzyme profile was used to train an SVR model for initial dosage prediction. Reinforcement Learning was subsequently applied to refine predictions through simulated feedback loops. Model performance was assessed using Mean Squared Error (MSE), R-squared (R²), and F1-score. Statistical comparisons between SVR predictions, RL-refined dosages, and physician-prescribed doses were performed using paired t-tests and one-way ANOVA. The SVR model achieved high predictive accuracy (MSE = 0.3554; R² = 0.9835), indicating its suitability for dosage estimation. The RL-refined model demonstrated a slight decrease in accuracy (MSE = 0.9928; R² = 0.9539). Statistical tests showed no significant improvement with RL (paired t-test: t = -1.1132, p = 0.2672; ANOVA: F = 0.0165, p = 0.9836). Mean predicted dosages across SVR, RL, and physician prescriptions were closely aligned (24.85 mg, 24.83 mg, and 24.93 mg, respectively). This study demonstrates that even standalone SVR may yield Propranolol dosage estimates with high accuracy, highlighting its prospective usefulness in clinical settings as a direct yet reliable tool for use in customized healthcare. While RL does offer some level of flexibility, the statistical value of improvements made was negligible, making RL beneficial but not necessarily critical. The proposed model shows that AI systems can aid in formulating evidence-based clinical judgments for dosing medications.

Journal of Information Systems and InformaticsVol. 7(2)
University of Uyo (NG), Topfaith University, Rivers State University (NG)
Openalex Percentile: Top 69%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.