Development of a care bundle for performing the newborn pulse oximetry screening by nursing staff

ABSTRACT Objective to describe the development of a bundle for the performance of pulse oximetry screening by nursing staff. Method this methodological study was conducted between October and December 2024 in a maternity hospital located in the interior of the state of Rio de Janeiro, Brazil. The development process occurred in three stages: identification of the informational needs of 27 nursing professionals regarding the pulse oximetry screening; literature review; and bundle development. Data analysis was performed using the IRaMuTeQ software with the Descending Hierarchical Classification method. Results the main informational needs reported by nursing staff were related to the use of the monitor, correct positioning, pulse oximetry parameters, appropriate timing for the test, result interpretation, and the need for retesting. The lack of training was widely mentioned. The bundle developed consists of four stages: before the test, test performance, result interpretation, and management of positive results. It includes nine items detailing the procedures, responsibilities, required checks, and spaces for verification. Conclusions and implications for practice the bundle, developed based on scientific evidence, facilitates adherence by providing clear and objective information. Its use contributes to minimizing errors and interpretation bias, while also systematizing the execution of the pulse oximetry screening. Furthermore, it strengthens care management and promotes continuing education in clinical practice.

Authors

Institutions

Publication Details

Journal
Escola Anna Nery
Published
2025-01-01
DOI
https://doi.org/10.1590/2177-9465-ean-2025-0006en
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a care bundle for performing the newborn pulse oximetry screening by nursing staff

Emanuel Nunes, Fernanda Maria Vieira Pereira-Ávila, Marcela de Abreu Moniz, Aline Cerqueira Santos Santana da Silva et al.
Escola Anna Nery
Non-Invasive Vital Sign Monitoring
article

Development of a care bundle for performing the newborn pulse oximetry screening by nursing staff

Emanuel Nunes, Fernanda Maria Vieira Pereira-Ávila, Marcela de Abreu Moniz, Aline Cerqueira Santos Santana da Silva, Fernanda Garcia Bezerra Góes, Giulianna Cardoso Gevú Maganha
article en

Abstract

ABSTRACT Objective to describe the development of a bundle for the performance of pulse oximetry screening by nursing staff. Method this methodological study was conducted between October and December 2024 in a maternity hospital located in the interior of the state of Rio de Janeiro, Brazil. The development process occurred in three stages: identification of the informational needs of 27 nursing professionals regarding the pulse oximetry screening; literature review; and bundle development. Data analysis was performed using the IRaMuTeQ software with the Descending Hierarchical Classification method. Results the main informational needs reported by nursing staff were related to the use of the monitor, correct positioning, pulse oximetry parameters, appropriate timing for the test, result interpretation, and the need for retesting. The lack of training was widely mentioned. The bundle developed consists of four stages: before the test, test performance, result interpretation, and management of positive results. It includes nine items detailing the procedures, responsibilities, required checks, and spaces for verification. Conclusions and implications for practice the bundle, developed based on scientific evidence, facilitates adherence by providing clear and objective information. Its use contributes to minimizing errors and interpretation bias, while also systematizing the execution of the pulse oximetry screening. Furthermore, it strengthens care management and promotes continuing education in clinical practice.

Escola Anna NeryVol. 29
Universidade Federal Fluminense (BR), Universidade de São Paulo (BR), Universidade Brasil (BR)
Openalex Percentile: Top 83%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.