A Low‐Cost Paper‐Based Microfluidic POCT Device for In Vitro Glucose Sensing Using Near‐Infrared Detection

ABSTRACT This study presents a low‐cost Near Infrared (NIR)‐based optical microfluidic POCT device for in vitro glucose detection on a paper‐based microfluidic platform. The device is made using a UV‐curable resin that has been widely used in the publishing industry, which is proposed as a low‐cost alternative to the expensive SU‐8 photoresist normally used in photolithography. A 940 nm NIR LED–photodiode system was incorporated to non‐invasively measure glucose levels. Glucose concentrations ranging from 62.5 to 1000 mg/dL were tested using only 3 µL of sample. To evaluate the effect of light intensity, three different LED currents (0.5, 0.75 and 1 mA) were applied. Output voltage ranged from approximately 570 to 700 mV and decreased with increasing glucose concentration, following Beer‐Lambert's law. Regression models yielded R 2 values above 97%, confirming the device's accuracy and its potential for real‐time, disposable, paper‐based microfluidic glucose monitoring in point‐of‐care settings.

Authors

Institutions

Publication Details

Journal
IET Science Measurement & Technology
Published
2025-01-01
DOI
https://doi.org/10.1049/smt2.70019
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low‐Cost Paper‐Based Microfluidic POCT Device for In Vitro Glucose Sensing Using Near‐Infrared Detection

Farhang Abbasi, Adel Pourmand, Kiana Kahyaei
2 links
IET Science Measurement & Technology
Biosensors and Analytical Detection
article

A Low‐Cost Paper‐Based Microfluidic POCT Device for In Vitro Glucose Sensing Using Near‐Infrared Detection

Farhang Abbasi, Adel Pourmand, Kiana Kahyaei
article en

Abstract

ABSTRACT This study presents a low‐cost Near Infrared (NIR)‐based optical microfluidic POCT device for in vitro glucose detection on a paper‐based microfluidic platform. The device is made using a UV‐curable resin that has been widely used in the publishing industry, which is proposed as a low‐cost alternative to the expensive SU‐8 photoresist normally used in photolithography. A 940 nm NIR LED–photodiode system was incorporated to non‐invasively measure glucose levels. Glucose concentrations ranging from 62.5 to 1000 mg/dL were tested using only 3 µL of sample. To evaluate the effect of light intensity, three different LED currents (0.5, 0.75 and 1 mA) were applied. Output voltage ranged from approximately 570 to 700 mV and decreased with increasing glucose concentration, following Beer‐Lambert's law. Regression models yielded R 2 values above 97%, confirming the device's accuracy and its potential for real‐time, disposable, paper‐based microfluidic glucose monitoring in point‐of‐care settings.

IET Science Measurement & TechnologyVol. 19(1)
Sahand University of Technology (IR)
Openalex Percentile: Top 83%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.