Dynamic analysis of variable-refrigerant-flow system integrated with baffled indirect evaporative cooler

An indirect evaporative cooler consumes minimal energy, as it operates without a compressor and maintains the absolute humidity of the cooled air. However, it should be combined with a traditional cooling system due to its low cooling efficiency and limited adaptability to variations in building cooling loads. Therefore, this study aims to evaluate a novel variable-refrigerant-flow (VRF) system featuring a baffled indirect evaporative cooler (BIEC), integrated into both the evaporator and condenser, through dynamic analysis under summer conditions in South Korea. Additionally, its performance is compared with a conventional VRF system to assess the impact of the BIEC. The numerical model for the VRF system was developed based on the manufacturer's technical data book, while the BIEC was developed using the number of transfer units method. The results confirmed that integrating the BIEC with the VRF system improved the cooling capacity and system coefficient of performance by 3.69% and 15.53%, respectively, while reducing power consumption by 11.52%. Thus, integrating a conventional VRF system with a BIEC effectively improves cooling performance for the building, confirming the feasibility of the proposed system. The findings of this study may contribute to the advancement and broader adoption of indirect evaporative cooling technology.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-07-26
DOI
https://doi.org/10.1016/j.csite.2025.106760
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic analysis of variable-refrigerant-flow system integrated with baffled indirect evaporative cooler

Kwang-Hwan Choi, Seong-Bhin Kim
1 citations
Case Studies in Thermal Engineering
Refrigeration and Air Conditioning Technologies
0.71
article

Dynamic analysis of variable-refrigerant-flow system integrated with baffled indirect evaporative cooler

Kwang-Hwan Choi, Seong-Bhin Kim
article en
1 citations

Abstract

An indirect evaporative cooler consumes minimal energy, as it operates without a compressor and maintains the absolute humidity of the cooled air. However, it should be combined with a traditional cooling system due to its low cooling efficiency and limited adaptability to variations in building cooling loads. Therefore, this study aims to evaluate a novel variable-refrigerant-flow (VRF) system featuring a baffled indirect evaporative cooler (BIEC), integrated into both the evaporator and condenser, through dynamic analysis under summer conditions in South Korea. Additionally, its performance is compared with a conventional VRF system to assess the impact of the BIEC. The numerical model for the VRF system was developed based on the manufacturer's technical data book, while the BIEC was developed using the number of transfer units method. The results confirmed that integrating the BIEC with the VRF system improved the cooling capacity and system coefficient of performance by 3.69% and 15.53%, respectively, while reducing power consumption by 11.52%. Thus, integrating a conventional VRF system with a BIEC effectively improves cooling performance for the building, confirming the feasibility of the proposed system. The findings of this study may contribute to the advancement and broader adoption of indirect evaporative cooling technology.

Case Studies in Thermal EngineeringVol. 74
Chonnam National University (KR), Ulsan National Institute of Science and Technology (KR)
Openalex Percentile: Top 30%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic analysis of variable-refrigerant-flow system integrated with baffled indirect evaporative cooler — Kwang-Hwan Choi, Seong-Bhin Kim · Case Studies in Thermal Engineering (2025) | TGRS Research Map | TGRS