Pilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance

With the access of large-scale renewable energy (wind energy, solar energy, etc.), renewable energy systems have fault characteristics such as amplitude limitation, frequency offset, and phase angle distortion compared to traditional power grids, which may lead to reduced sensitivity of conventional pilot protection or even failure/maloperation. To ensure the reliable identification of transmission line fault in large-scale renewable energy systems, a novel pilot protection based on morphological similarity distance is proposed and the corresponding protection threshold determination method is elaborated. The proposed pilot protection utilizes the similarity of the current waveforms at both ends of the transmission line to construct the protection criterion, and can still operate reliably even under the fault resistance of 300 Ω. To verify the effectiveness of the proposed protection, extensive hardware-in-loop experiments based on real time digital simulator are conducted refer to the dynamic simulation test benchmark.

Authors

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-07-26
DOI
https://doi.org/10.1016/j.ijepes.2025.110936
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance

Guibin Zou, Kuan‐Ching Li, Xiuyan Wei, Shuo Zhang et al.
1 citations
International Journal of Electrical Power & Energy Systems
Power Systems Fault Detection
1.21
article

Pilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance

Guibin Zou, Kuan‐Ching Li, Xiuyan Wei, Shuo Zhang, Qiang Huang
article en
1 citations

Abstract

With the access of large-scale renewable energy (wind energy, solar energy, etc.), renewable energy systems have fault characteristics such as amplitude limitation, frequency offset, and phase angle distortion compared to traditional power grids, which may lead to reduced sensitivity of conventional pilot protection or even failure/maloperation. To ensure the reliable identification of transmission line fault in large-scale renewable energy systems, a novel pilot protection based on morphological similarity distance is proposed and the corresponding protection threshold determination method is elaborated. The proposed pilot protection utilizes the similarity of the current waveforms at both ends of the transmission line to construct the protection criterion, and can still operate reliably even under the fault resistance of 300 Ω. To verify the effectiveness of the proposed protection, extensive hardware-in-loop experiments based on real time digital simulator are conducted refer to the dynamic simulation test benchmark.

International Journal of Electrical Power & Energy SystemsVol. 170
State Grid Shandong Electric Power Company
Affordable and clean energy
Openalex Percentile: Top 19%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pilot protection for transmission line of large-scale renewable energy system based on morphological similarity distance — Guibin Zou, Kuan‐Ching Li, et al. · International Journal of Electrical Power & Energy Systems (2025) | TGRS Research Map | TGRS