Degradation of anti-wear additives and tribological properties of engine oils at extended oil change intervals in city buses

The article presents the results of combined tribological and physicochemical studies of engine oils used in Autosan Sancity M12LF city buses at various mileages exceeding the manufacturer's recommended oil change interval (60,000 km). Semi-synthetic oil of ACEA E4, E7, SAE 10W-40 class was analyzed, with samples taken from five buses with different degrees of interval exceedance (- 19% to + 35%). To address outlier influence, both classical Pearson and a more robust Spearman's rank correlations were applied. While Pearson correlation suggested a very strong relationship (r = - 0.9946) between sulfur content and wear scar diameter, Spearman's robust method confirmed a strong but more reliable association (r = - 0.810), indicating that classical correlation was inflated by outliers. A potential relationship was demonstrated between the degree of oil change interval exceedance and degradation of phosphate anti-wear additives. Anti-wear additive degradation follows a non-linear pattern and accelerates with successive exceedances of the recommended change interval. A degradation thresholds were identified: oil degradation becomes more pronounced after exceeding the interval by 10,000-15,000 km, while exceeding by more than 15,000-20,000 km results in potentialy increased engine component wear and elevated failure risk. The content of abrasive metals (Fe, Cu) in used oils significantly increased compared to fresh oil, with particularly high iron concentration (131.67 ppm) observed in the sample with the greatest interval exceedance. After exceeding the interval by 20,000 km, phosphate anti-wear additive depletion was 73% higher than when exceeding by 5000 km. The research results provide important information for bus fleet operators, allowing more precise determination of engine oil change intervals, which translates into extended engine life and reduced operating costs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-07-26
DOI
https://doi.org/10.1038/s41598-025-12480-y
Citations
5
Primary Topic
Lubricants and Their Additives
Type
article
Field-Weighted Citation Impact
3.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Degradation of anti-wear additives and tribological properties of engine oils at extended oil change intervals in city buses

Wojciech Gołębiowski, Rafał Krakowski, Grzegorz Zając
5 citations
Scientific Reports
Lubricants and Their Additives
3.57
article

Degradation of anti-wear additives and tribological properties of engine oils at extended oil change intervals in city buses

Wojciech Gołębiowski, Rafał Krakowski, Grzegorz Zając
article en
5 citations

Abstract

The article presents the results of combined tribological and physicochemical studies of engine oils used in Autosan Sancity M12LF city buses at various mileages exceeding the manufacturer's recommended oil change interval (60,000 km). Semi-synthetic oil of ACEA E4, E7, SAE 10W-40 class was analyzed, with samples taken from five buses with different degrees of interval exceedance (- 19% to + 35%). To address outlier influence, both classical Pearson and a more robust Spearman's rank correlations were applied. While Pearson correlation suggested a very strong relationship (r = - 0.9946) between sulfur content and wear scar diameter, Spearman's robust method confirmed a strong but more reliable association (r = - 0.810), indicating that classical correlation was inflated by outliers. A potential relationship was demonstrated between the degree of oil change interval exceedance and degradation of phosphate anti-wear additives. Anti-wear additive degradation follows a non-linear pattern and accelerates with successive exceedances of the recommended change interval. A degradation thresholds were identified: oil degradation becomes more pronounced after exceeding the interval by 10,000-15,000 km, while exceeding by more than 15,000-20,000 km results in potentialy increased engine component wear and elevated failure risk. The content of abrasive metals (Fe, Cu) in used oils significantly increased compared to fresh oil, with particularly high iron concentration (131.67 ppm) observed in the sample with the greatest interval exceedance. After exceeding the interval by 20,000 km, phosphate anti-wear additive depletion was 73% higher than when exceeding by 5000 km. The research results provide important information for bus fleet operators, allowing more precise determination of engine oil change intervals, which translates into extended engine life and reduced operating costs.

Scientific ReportsVol. 15(1)
University of Life Sciences in Lublin (PL), Gdynia Maritime University (PL)
Uniwersytet Przyrodniczy w Lublinie, Wydział Inżynierii Produkcji, Uniwersytetu Przyrodniczego w Lublinie
Sustainable cities and communities
Openalex Percentile: Top 7%
Lubricants and Their Additives
3.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.