A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency

The usability and versatility of autoinjectors in managing chronic and autoimmune diseases have made them increasingly attractive in medicine. However, investigations into autoinjector designs require an understanding of the kinematic properties and fluid behaviour during injection. To optimise injection efficiency, this study develops a mathematical and computational fluid dynamics (CFD) model of an IM autoinjector by investigating the effects of viscosity, needle length, needle diameter, and medication volume on the injection process. The model was verified and validated using a comparator experiment and optimised using a parameter sensitivity analysis. The mathematical model results show plunger displacement increases linearly in low viscous fluids (v < 20 cP), allowing faster injections. CFD simulations show that high-viscosity fluids (v > 20 cP) reduce injectability and increase syringeability. Needle gauges below 20 exhibited constant dynamic pressure and negligible shear stress, while gauges between 20 and 25 showed higher shear stress and pressure variability. Longer needles and larger medication volumes increase dynamic pressure and shear stress, prolonging injection time. The mathematical and CFD models matched experimental measurements within a 1.1 % and 4.8 % margin of error, respectively. These findings inform the design of efficient autoinjectors, enhancing drug delivery, patient comfort, and compliance.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2025-07-26
DOI
https://doi.org/10.1016/j.medengphy.2025.104407
Primary Topic
Viral Infectious Diseases and Gene Expression in Insects
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency

Chibuike Mbanefo, Malebogo Ngoepe, Sudesh Sivarasu, Ntokozo Magubane
Medical Engineering & Physics
Viral Infectious Diseases and Gene Expression in Insects
article

A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency

Chibuike Mbanefo, Malebogo Ngoepe, Sudesh Sivarasu, Ntokozo Magubane
article en

Abstract

The usability and versatility of autoinjectors in managing chronic and autoimmune diseases have made them increasingly attractive in medicine. However, investigations into autoinjector designs require an understanding of the kinematic properties and fluid behaviour during injection. To optimise injection efficiency, this study develops a mathematical and computational fluid dynamics (CFD) model of an IM autoinjector by investigating the effects of viscosity, needle length, needle diameter, and medication volume on the injection process. The model was verified and validated using a comparator experiment and optimised using a parameter sensitivity analysis. The mathematical model results show plunger displacement increases linearly in low viscous fluids (v < 20 cP), allowing faster injections. CFD simulations show that high-viscosity fluids (v > 20 cP) reduce injectability and increase syringeability. Needle gauges below 20 exhibited constant dynamic pressure and negligible shear stress, while gauges between 20 and 25 showed higher shear stress and pressure variability. Longer needles and larger medication volumes increase dynamic pressure and shear stress, prolonging injection time. The mathematical and CFD models matched experimental measurements within a 1.1 % and 4.8 % margin of error, respectively. These findings inform the design of efficient autoinjectors, enhancing drug delivery, patient comfort, and compliance.

Medical Engineering & PhysicsVol. 144(1)
University of Cape Town (ZA)
National Research Foundation, University of Cape Town
Affordable and clean energy
Openalex Percentile: Top 84%
Viral Infectious Diseases and Gene Expression in Insects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency — Chibuike Mbanefo, Malebogo Ngoepe, et al. · Medical Engineering & Physics (2025) | TGRS Research Map | TGRS