Test beam characterization of a digital silicon photomultiplier

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single photon avalanche diodes (SPADs) in commercial CMOS processes creates the opportunity to combine a matrix of SPADs and an application-specific integrated circuit in the same die. The potential of such digital SiPMs (dSiPMs) is still being explored, while it already is an established technology in certain applications, like light detection and ranging (LiDAR). A prototype dSiPM, produced in the LFoundry 150-nm CMOS technology, was designed and tested at DESY. The dSiPM central part is a matrix of 32 by 32 pixels. Each pixel contains four SPADs, a digital front-end, and has an area of 69 . 6 × 76 µm 2 . The chip has four time-to-digital converters and includes further circuitry for data serialization and data links. This work focuses on the characterization of the prototype in an electron beam at the DESY II Test Beam facility, to study its capability as a tracking and timing detector for minimum ionizing particles (MIPs). The MIP detection efficiency is found to be dominated by the fill factor and on the order of 31 %. The position of the impinging MIPs can be measured with a precision of about 20 µm, and the time of the interaction can be measured with a precision better than 50 ps for about 85 % of the detected events. In addition, laboratory studies on the breakdown voltage, dark count rate, and crosstalk probability, as well as the experimental methods required for the characterization of such a sensor type in a particle beam are presented.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-07-26
DOI
https://doi.org/10.1016/j.nima.2025.170874
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test beam characterization of a digital silicon photomultiplier

Daniil Rastorguev, K. Hansen, Gianpiero Vignola, Simon Spannagel et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radiation Detection and Scintillator Technologies
article

Test beam characterization of a digital silicon photomultiplier

Daniil Rastorguev, K. Hansen, Gianpiero Vignola, Simon Spannagel, Inge Diehl, Finn Feindt, T. Vaňát, Frauke Poblotzki, Stephan Lachnit, Ingrid-Maria Gregor, Ono Feyens
article en

Abstract

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single photon avalanche diodes (SPADs) in commercial CMOS processes creates the opportunity to combine a matrix of SPADs and an application-specific integrated circuit in the same die. The potential of such digital SiPMs (dSiPMs) is still being explored, while it already is an established technology in certain applications, like light detection and ranging (LiDAR). A prototype dSiPM, produced in the LFoundry 150-nm CMOS technology, was designed and tested at DESY. The dSiPM central part is a matrix of 32 by 32 pixels. Each pixel contains four SPADs, a digital front-end, and has an area of 69 . 6 × 76 µm 2 . The chip has four time-to-digital converters and includes further circuitry for data serialization and data links. This work focuses on the characterization of the prototype in an electron beam at the DESY II Test Beam facility, to study its capability as a tracking and timing detector for minimum ionizing particles (MIPs). The MIP detection efficiency is found to be dominated by the fill factor and on the order of 31 %. The position of the impinging MIPs can be measured with a precision of about 20 µm, and the time of the interaction can be measured with a precision better than 50 ps for about 85 % of the detected events. In addition, laboratory studies on the breakdown voltage, dark count rate, and crosstalk probability, as well as the experimental methods required for the characterization of such a sensor type in a particle beam are presented.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1081
Deutsches Elektronen-Synchrotron DESY (DE)
Helmholtz-Gemeinschaft, Helmholtz Association
Affordable and clean energy
Openalex Percentile: Top 75%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.