Comparison of surgical and postoperative pregnancy outcomes between electrotomy and cold instruments for hysteroscopic myomectomy: a single-center, 3-year retrospective study
Cold instruments for hysteroscopic myomectomy seem to be a safe and feasible surgical procedure. It has an advantage over electrotomy in terms of complete removal of submucosal fibroids. Moreover, cold instruments for hysteroscopic myomectomy have no electrothermal damage to normal endometrium, which is favorable for pregnancy as soon as possible after surgery.
Authors
- Manchao Li (ORCID: https://orcid.org/0000-0001-5405-0116)
- Yujie Li (ORCID: https://orcid.org/0000-0002-2359-2673)
- Lei Jia (ORCID: https://orcid.org/0000-0002-7727-9316)
- Cong Fang (ORCID: https://orcid.org/0000-0001-9352-9525)
- Panyu Chen
- Weie Zhao
- Danqi Shao
Institutions
- Guangdong University of Technology (CN)
- Sun Yat-sen University (CN)
- Sixth Affiliated Hospital of Sun Yat-sen University (CN)
Publication Details
- Journal
- Archives of Gynecology and Obstetrics
- Published
- 2025-07-26
- DOI
- https://doi.org/10.1007/s00404-025-08131-2
- Primary Topic
- Uterine Myomas and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China