New Analytical Method Development and Validation of Molnupiravir in Bulk and Formulation

A straightforward, sensitive, exact, and approved RP-HPLC a methodology has been developed to analyse Molnupiravir API and for its stability-indicating assay. Molnupiravir exhibits its greatest absorbance at 236nm when measured with a UV/Visible detector. The solvent solution and wavelength were modified to maximize the sensitivity of the proposed method. Using a C18 column that measures 250mm, 4.6mm, and 5m, an HPLC system from Waters 2489 uses acetonitrile and water in a 60:40 ratio. The resilience, linearity, specificity, robustness, and precision of the approach were all validated. For the concentration range of 1–32ug/ml, a mean correlation coefficient of 0.9997 was found, indicating linearity. The suggested method recovered MOL between 99.77% and 100.26%. 1.15μg Ml − 1 and 3.50μg mL−1 were the limits of detection (LOD) and quantification (LOQ), respectively. It was proved that the new RP-HPLC process was precise, accurate, and stable indicating. It is useful in the manufacturing of medications containing APIs. When the strategy was validated using the ICH recommendations and the methodologies given, there were no noticeable differences.

Authors

Institutions

Publication Details

Journal
Research Journal of Pharmacy and Technology
Published
2025-06-12
DOI
https://doi.org/10.52711/0974-360x.2025.00354
Primary Topic
SARS-CoV-2 and COVID-19 Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Analytical Method Development and Validation of Molnupiravir in Bulk and Formulation

Nagarajan Kandasamy, Remica Aggarwal, Pankaj Bhatt, Bhavik Khatter
Research Journal of Pharmacy and Technology
SARS-CoV-2 and COVID-19 Research
article

New Analytical Method Development and Validation of Molnupiravir in Bulk and Formulation

Nagarajan Kandasamy, Remica Aggarwal, Pankaj Bhatt, Bhavik Khatter
article en

Abstract

A straightforward, sensitive, exact, and approved RP-HPLC a methodology has been developed to analyse Molnupiravir API and for its stability-indicating assay. Molnupiravir exhibits its greatest absorbance at 236nm when measured with a UV/Visible detector. The solvent solution and wavelength were modified to maximize the sensitivity of the proposed method. Using a C18 column that measures 250mm, 4.6mm, and 5m, an HPLC system from Waters 2489 uses acetonitrile and water in a 60:40 ratio. The resilience, linearity, specificity, robustness, and precision of the approach were all validated. For the concentration range of 1–32ug/ml, a mean correlation coefficient of 0.9997 was found, indicating linearity. The suggested method recovered MOL between 99.77% and 100.26%. 1.15μg Ml − 1 and 3.50μg mL−1 were the limits of detection (LOD) and quantification (LOQ), respectively. It was proved that the new RP-HPLC process was precise, accurate, and stable indicating. It is useful in the manufacturing of medications containing APIs. When the strategy was validated using the ICH recommendations and the methodologies given, there were no noticeable differences.

Research Journal of Pharmacy and Technology
Institute of Management Technology (IN), CT Group Of Institutions (IN)
Openalex Percentile: Top 77%
SARS-CoV-2 and COVID-19 Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

New Analytical Method Development and Validation of Molnupiravir in Bulk and Formulation — Nagarajan Kandasamy, Remica Aggarwal, et al. · Research Journal of Pharmacy and Technology (2025) | TGRS Research Map | TGRS