Development of small bone implants using a mean shape bone in a porcine model for carpal bone replacement

The development of innovative small bone replacements for the human wrist has been partially limited by the lack of a suitable preclinical animal model. This study explores the feasibility of using the Yucatan minipig (YMP) as a preclinical model for small bone replacement. Implants for the radial carpal bone (RCB), homologous to the human scaphoid, were developed for a pilot in vivo animal study. RCB size (volume, bounding box dimensions) was quantified (<i>n</i> = 35), and relationships between animal age, weight, and RCB volume were investigated. Bounding box dimensions were also analyzed relative to RCB volume. A mean-shaped RCB model was generated using ShapeWorks Studio and scaled to create a set of implants. These implants were evaluated in a pilot in vivo study, where the distances between the explanted bone surface and both the predicted and surgeon-selected implant surfaces were recorded for each animal. Predicted implant distances (0.8 ± 0.2 mm), were larger (<i>p</i> < 0.001) than surgeon-selected implant distances (0.4 ± 0.1 mm) in three animals. In one animal, the predicted implant distances (0.3 ± 0.2 mm) were smaller (<i>p</i> < 0.0001) than the surgeon-selected implant distances (0.5 ± 0.3 mm). The set of implants generated provided the surgeon with options suitable for the range of animals in the in vivo study. This study presents a novel approach to generating small bone replacements by scaling a mean-shaped bone in a porcine model and further evaluates the YMP as a preclinical model for small bone replacement in the human wrist.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2025-07-24
DOI
https://doi.org/10.1177/09544119251355382
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of small bone implants using a mean shape bone in a porcine model for carpal bone replacement

Joseph J. Crisco, Douglas C. Moore, Amy M. Morton, Edward Akelman et al.
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Orthopedic Surgery and Rehabilitation
article

Development of small bone implants using a mean shape bone in a porcine model for carpal bone replacement

Joseph J. Crisco, Douglas C. Moore, Amy M. Morton, Edward Akelman, Quianna M Vaughan
article en

Abstract

The development of innovative small bone replacements for the human wrist has been partially limited by the lack of a suitable preclinical animal model. This study explores the feasibility of using the Yucatan minipig (YMP) as a preclinical model for small bone replacement. Implants for the radial carpal bone (RCB), homologous to the human scaphoid, were developed for a pilot in vivo animal study. RCB size (volume, bounding box dimensions) was quantified (<i>n</i> = 35), and relationships between animal age, weight, and RCB volume were investigated. Bounding box dimensions were also analyzed relative to RCB volume. A mean-shaped RCB model was generated using ShapeWorks Studio and scaled to create a set of implants. These implants were evaluated in a pilot in vivo study, where the distances between the explanted bone surface and both the predicted and surgeon-selected implant surfaces were recorded for each animal. Predicted implant distances (0.8 ± 0.2 mm), were larger (<i>p</i> < 0.001) than surgeon-selected implant distances (0.4 ± 0.1 mm) in three animals. In one animal, the predicted implant distances (0.3 ± 0.2 mm) were smaller (<i>p</i> < 0.0001) than the surgeon-selected implant distances (0.5 ± 0.3 mm). The set of implants generated provided the surgeon with options suitable for the range of animals in the in vivo study. This study presents a novel approach to generating small bone replacements by scaling a mean-shaped bone in a porcine model and further evaluates the YMP as a preclinical model for small bone replacement in the human wrist.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineVol. 239(8)
Brown University (US)
National Institute of Arthritis and Musculoskeletal and Skin Diseases
Openalex Percentile: Top 69%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.