Development of reusable screen-printed ion-selective electrodes with calibration-free operation

The reusable solid-state calibration-free screen-printed ion-selective electrodes (SP-ISEs) have been developed with a carbon paste and PEDOT: PEDOT-S (<i>S</i>=sulfonated) back contact. The calibration-free Na<sup>+</sup> and Ca<sup>2+</sup> SP-ISEs showed a near Nernstian response of 52.1 ± 2.0 mV/log [a<sub>Na+</sub>] and 27.3 ± 0.8 mV/log [a<sub>Ca2+</sub>] respectively while holding a stable intercept for multiple calibrations across batches for 12 h and over 7 days. The unique carbon paste and PEDOT: PEDOT-S copolymer combined back contact on carbon substrate allowed us to fix the intercept with a constant low current treatment across different ionophores for both monovalent Na<sup>+</sup> and divalent Ca<sup>2+</sup> cations. This treatment imparts exceptional potential stability, leading to highly overlapping calibration curves for individual ISEs across multiple measurement cycles, demonstrating their reusability in a calibration-free mode. These SP-ISEs maintained their respective selectivity against major interfering ions and were able to operate reproducibly despite prolonged dry storage without any curing solution, as tested for a total of 28 days. The practical utility of these sensors was validated by analyzing environmental samples, determining Na<sup>+</sup> and Ca<sup>2+</sup> concentrations in tap water (934 ± 37 μM and 194 ± 11 μM respectively) and hydroponics solutions (757 ± 43 μM and 7047 ± 565 μM respectively). This integration of high-performance characteristics on an economical carbon-based substrate creates sensors that are simultaneously affordable enough to be disposable yet stable enough to be reusable, effectively bridging the critical gap between sophisticated laboratory systems and scalable, field-deployable solid ISEs for environmental monitoring applications.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2025-07-24
DOI
https://doi.org/10.1016/j.snr.2025.100367
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of reusable screen-printed ion-selective electrodes with calibration-free operation

Dipankar Koley, Pavel Sengupta, Chloe Ramsperger
2 citations
Sensors and Actuators Reports
Analytical Chemistry and Sensors
1.47
article

Development of reusable screen-printed ion-selective electrodes with calibration-free operation

Dipankar Koley, Pavel Sengupta, Chloe Ramsperger
article en
2 citations

Abstract

The reusable solid-state calibration-free screen-printed ion-selective electrodes (SP-ISEs) have been developed with a carbon paste and PEDOT: PEDOT-S (<i>S</i>=sulfonated) back contact. The calibration-free Na<sup>+</sup> and Ca<sup>2+</sup> SP-ISEs showed a near Nernstian response of 52.1 ± 2.0 mV/log [a<sub>Na+</sub>] and 27.3 ± 0.8 mV/log [a<sub>Ca2+</sub>] respectively while holding a stable intercept for multiple calibrations across batches for 12 h and over 7 days. The unique carbon paste and PEDOT: PEDOT-S copolymer combined back contact on carbon substrate allowed us to fix the intercept with a constant low current treatment across different ionophores for both monovalent Na<sup>+</sup> and divalent Ca<sup>2+</sup> cations. This treatment imparts exceptional potential stability, leading to highly overlapping calibration curves for individual ISEs across multiple measurement cycles, demonstrating their reusability in a calibration-free mode. These SP-ISEs maintained their respective selectivity against major interfering ions and were able to operate reproducibly despite prolonged dry storage without any curing solution, as tested for a total of 28 days. The practical utility of these sensors was validated by analyzing environmental samples, determining Na<sup>+</sup> and Ca<sup>2+</sup> concentrations in tap water (934 ± 37 μM and 194 ± 11 μM respectively) and hydroponics solutions (757 ± 43 μM and 7047 ± 565 μM respectively). This integration of high-performance characteristics on an economical carbon-based substrate creates sensors that are simultaneously affordable enough to be disposable yet stable enough to be reusable, effectively bridging the critical gap between sophisticated laboratory systems and scalable, field-deployable solid ISEs for environmental monitoring applications.

Sensors and Actuators ReportsVol. 10
Oregon State University (US)
National Institute of Dental and Craniofacial Research
Affordable and clean energy
Openalex Percentile: Top 17%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of reusable screen-printed ion-selective electrodes with calibration-free operation — Dipankar Koley, Pavel Sengupta, et al. · Sensors and Actuators Reports (2025) | TGRS Research Map | TGRS